Download Print this page

Function Test / Possible Sources Of Error - raumplus S34 Manual

Sliding door brake
Hide thumbs Also See for S34:

Advertisement

Function test
function test
Trouble shooting
Error
The sliding door does not brake.
The sliding door does not brake
properly,
it`s grinds while closing.
The sliding door closes too early
or too late.
Imprecise overlap of the vertical
profiles for systems with more
than two sliding doors.
Noise when opening or closing the
sliding door.
The sliding door closes too slowly.
3 x
Funktionstest
In order to avoid an influence of the closing quality of the sliding door brake,
we recommend not to use a dust excluding brush between the stiles.
Troubleshooting
Stretch the carrier of the sliding
door brake.
Make sure that the top cap has the
right size.
Correct the position of the posi-
tioning.
Make sure that the bottom stopper
is on the correct position.
Make sure that the positioning is
mounted at right angles.
Make sure that the screws of the
positioning are not too tight.
Turn the door height adjustment
max. one step down to increase
the distance between driver and
cut surface of the position.
Make sure the floor is flush, if
necessary exchange the sliding
door brake.
For slopes you need a sliding door
brake for higher weight category.
USA / CANADA 1 866 580 0112
raumplusna.com
11

Hide quick links:

Advertisement

loading

This manual is also suitable for:

S42S26S1200