Summary of Contents for VICI DBS MISTRAL EVOLUTION HYBRID
Page 1
MISTRAL EVOLUTION HYBRID USER MANUAL www.vicidbs.com TECH SUPPORT VICI AG INTERNATIONAL Europe, Asia, Africa, Australia & New Zealand: Parkstrasse 2 techsupport@vicidbs.com CH-6214 Schenkon Switzerland USA, Canada, Central & South America: techsupportusa@vicidbs.com tel: +41 41 925-6200 fax: +41 41 925-6201 Italy web: www.vicidbs.com...
MISTRAL EVOLUTION HYBRID USER MANUAL www.vicidbs.com 1. VERSION HISTORY VERSION DATE COMMENT/CHANGE 1.00.0100 01/10/2017 Layout and initial release, VICI DBS 1.01.0000 12/20/2018 Update 1.02.0000 05/18/2020 New layout, images and graphics, VICI Gig Harbor Group 1.03.0000 07/01/2021 Updated schematics, update to details on 9.3, add chapters 12-13...
2. INTRODUCTION The VICI DBS® Mistral Evolution Hybrid is a self contained generator that produces up to 12 L/min of high purity nitrogen and 22 L/min of air. The generator is designed to meet the specific requirements of the Sciex LC/MS.
When using your Mistral Evolution Hybrid, basic safety precautions should always be followed, including the following: • The Mistral Evolution Hybrid is a Nitrogen Generator. Do not let it run with the outlet open to the air in a low volume room. •...
MISTRAL EVOLUTION HYBRID USER MANUAL www.vicidbs.com 5. PRESENTATION OF THE DEVICE 5.1 Front View Backlit Display LED Indicator Lights Command Buttons (x3) 5.2 Back View Relay Alarm Outlet N2 with Valve Outlet Compressor On/Off Switch Box Cooling System Outlet Pressure...
MISTRAL EVOLUTION HYBRID USER MANUAL www.vicidbs.com 5.3 Connections Power Supply: C-20 Outlet N2 with Valve: G1/4” female Outlet Water Purge: Ø10mm tube Relay Alarm: 2 pos universal Mate-N-Lock connector female 5.4 Power Supply Settings The current power supply setting of the device is indicated on the ID Sticker on the back of the device. The Mistral Evolution standard setting is 210-230V/50-60Hz.
Evolution Hybrid could be elevated from any points under the chassis base. Recommendations for the transport When the instrument is shipped back to the factory for recalibration or repair, the Mistral Evolution Hybrid should be packed in its original packing with the inlets and outlets protected against any accidental penetration of dust or particles of the package.
MISTRAL EVOLUTION HYBRID USER MANUAL www.vicidbs.com 6.2. Electrical volution Hybrid Date: THIS DOCUMENT AND THE INFORMATION WHICH Rev.: IT CONTAINS SHALL NOT BE USED, EXPLOITED diagram Created: 11.06.21 OR SOLD, AND SHALL NOT BE REVEALED OR ECN no DISCLOSED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF VICI.
MISTRAL EVOLUTION HYBRID USER MANUAL www.vicidbs.com 7. STARTING THE GENERATOR • Read the Operations Manual carefully. • Do not place the Mistral Evolution on a sloping area, use the wheel breaks. • Make sure the voltage setting is correct • The power supply main cable connector is the disconnect device in case of emer- gency, it must be easily accessible at anytime.
MISTRAL EVOLUTION HYBRID USER MANUAL www.vicidbs.com 8. SOFTWARE 8.1. Overview of the Menus The Mistral Evolution has the following menus: PARAMETER Used to set the different parameters CONFIGURE Only available to trained individuals; password protected DIAGNOSTIC Used to see the different values of the sensors...
MISTRAL EVOLUTION HYBRID USER MANUAL www.vicidbs.com 8.3. Diagnostic ITEM DESCRIPTION Temperature Shows the instant temperature in the cabinet Outlet Pressure Shows the instant outlet pressure Int. Tank Pressure Shows the instant pressure in the internal reservoir Comp. Work Time Shows the work time of the compressor...
9.3. Recommended Set-Up As the size of the tank will be large for application (and legislation is different from one country to another), VICI DBS does not sell this product allowing the customer to purchase it locally. Relief valve set...
MISTRAL EVOLUTION HYBRID USER MANUAL www.vicidbs.com 10. ALARMS & PRE-ALARMS 10.1. Pre-Alarms Precursors of the alarms. Do not stop the device. ITEM DESCRIPTION Temperature The temperature inside the cabinet is over the maximum limit. Check if the room temperature respects the specifications and if there is enough space in the rear side of the unit for the ventilation.
11. TROUBLESHOOTING • Please refer to the service manual before self-servicing Mistral Evolution. • Please contact our service department before self-servicing. • If the device is self-serviced without an agreement with VICI DBS Service Department, the warranty will be void. PROBLEM...
MISTRAL EVOLUTION HYBRID USER MANUAL www.vicidbs.com 12. MAINTENANCE 12.1. 4000h Maintenance Every 4,000h the intake air filter, outlet silencer and cartridges must be replaced. DB-10618 Maintenance kit 4000h for Mistral Evolution Hybrid includes: 1 - white silencer 3 - blue silencers 3 - cartridges 12.2.
Page 18
MISTRAL EVOLUTION HYBRID USER MANUAL www.vicidbs.com DB-EVO-013 Internal Ventilator Fan DB-EVO-014 Pressure Sensor DB-EVO-015 Coalescent Filter AF30 - cartridge not included DB-EVO-016 Valve Connector (illuminated) DB-EVO-017 Pneumatic Valve 3/2 Waircom DB-EVO-018 Complete Electrovalve 3-way DB-N-FIL004 Filter AF20 with cartridge DB-EVO-021...
Need help?
Do you have a question about the MISTRAL EVOLUTION HYBRID and is the answer not in the manual?
Questions and answers