9 inches to 13 inches (approx.23 cm to 33 cm) and for home use. MOCAarm detects the appearance of irregular heartbeats during measurement; an indicated symbol will appear with measuring reading. And the BP Category Indicator will show the information with the readings on the screen for the user tracking their blood pressure level.
ABOUT BLOOD PRESSURE 1. What is blood pressure? Blood pressure is the measurement of the force of blood pushing against the walls of the arteries. Arterial blood pressure is constantly fluctuating during the course of the cardiac cycle. The highest pressure in the cycle is called the systolic blood pressure, and represents the pressure in the artery when the heart is beating.
Page 6
WHO blood pressure classifications: Standards for assessment of high or low blood pressure without re g a rd to a g e, h a v e b e e n e s t a b l i s h e d b y t h e Wo r l d H e a l t h Organization (WHO), as shown in the chart.
Page 7
Variations in blood pressure: Individual blood pressures vary greatly both on a daily and a seasonal basis. These variations are even more pronounced in hyper tense patients. Normally the blood pressure rises while at work and is at its lowest during sleeping period. (hyper tense: means a person who has high blood pressure symptom.) The graph below illustrated the variations in blood pressure over a whole day with measurement taken every five minutes.
Page 8
PRECAUTIONS * Read the Instruction Manual thoroughly before measuring and keep it at hand for your reference at any time. * The device is designed for home use and not suitable for clinical use. * The patient is an intended operator, who can operate the device by himself or herself, not necessarily by a physician or operator.
Page 9
When used among medical electronic equipments on the same limb, ● pressurization of the cuff may cause temporarily malfunction to other devices. If you have one of the circulatory problems as arteriosclerosis, diabetes, liver ● disease, kidney disease, severe hypertension, peripheral circulation….., please consult your healthcare professional before using the device.
Arm Cuff Hole BP Category Indicator LCD Display DC Jack 6V 1A AC/DC Adapter (Excluded) Mode Button Blood Pressure Cuff Down Button Cuff Extension Tube START / STOP Button Storage Case Memory Button AAA “LR03” (1.5V) UP Button Alkaline Battery X 4 Bluetooth Indicator Caution! Substitution of a component different from that supplied might result in...
SYMBOL DEFINITIONS Unit display Month / Date Hour : Minute (Also represents YEAR in Bluetooth Symbol Setting Mode) Blood Pressure Unit Systolic Pressure Memory Record Number BP Category Indicator Low Battery Symbol Diastolic Pressure Pulse Symbol Irregular Heartbeat Detector Heart Rate | 09 |...
Page 13
Symbols Definitions This symbol appears when the battery power is excessively low or the polarity reverses. Low Battery Symbol * We suggest you replace all batteries with new ones, and make sure the +/- polarities are properly positioned. Once pulse is detected, the symbol flashes with each pulse beat. * Our suggestion: Pulse Symbol Please do not talk or move during measurements.
Page 14
FEATURES BP Category Indicator This device is equipped with BP Category Indicator which classifies your blood pressure measurements into six stages (Optimal to Severe hypertension) as shown in below chart: Stages of Blood Systolic Diastolic Recommendations by SIGN 49: Color Pressure Levels (mmHg) (mmHg)
Page 15
After each measurement is completed, LCD display will show your position automatically on the six segments of the bar indicator which corresponds to BP Category Indicator. Green Yellow Orange ● ● ● ● ● ● Severe Hypertension Moderate Hypertension Mild Hypertension Hight-Normal Normal Optimal...
Irregular Heartbeat Detector The symbol will appear on screen indicating a certain heartbeat irregularity was detected during measurement. The heartbeat rhythm that is more than or less than 25% from the average rhythm is usually defined as an irregular heartbeat rhythm. Ta l k i n g , m o v i n g , s h a k i n g o r a n i r r e g u l a r p u l s e d u r i n g t h e measurement can result in the appearance of this symbol.
BLUETOOTH TRANSMISSION Bluetooth Communication Function MOCAarm features a built-in Bluetooth Communication function, which enables the device automatically transmit measuring results to paired Bluetooth device. When connection established, BPM would transmit memory data such as Measure Date, Systolic Pressure, Diastolic Pressure and Pulse Rate to the Bluetooth device.
Page 18
Bluetooth device. Moving away from the source of the interference or turning off these devices to resolve the problem. . Make sure MOCAarm and paired Bluetooth device are within acceptable distance (no more than 10 meters) with each other. If not, put them closer.
INSTALLING BATTERIES When LOW BATTERY SYMBOL appears on the display, or no reaction toward operation, please change batteries. Replace all worn-out batteries with new ones and do not mix new and used batteries. Do not mix alkaline, standard (carbon-zinc) or rechargeable (cadmium) batteries either.
USING THE AC/DC ADAPTER This monitor is designed for operation with batteries or an AC/DC adapter. Please use only a compatible AC/DC adapter with required voltage and current as indicated in this manual. Note! . No batteries are needed when operating with an AC/DC adapter. ....
Page 21
Put left arm through the cuff loop. The tube should lie over the ● brachial artery on the inner part of the arm. The bottom edge of the cuff should be 2 ~ 3 cm (approx. 1 inch) above the inner elbow. Pull the end of the cuff so that the top and bottom edges are ●...
Page 22
Sit on a chair comfortably, put your feet flat on the floor and lay ● your forearm on the table, make sure your back and arm supported, legs uncrossed, so that the cuff is at the same level as your heart. Relax your arm and turn your arm upward.
MEASUREMENT PROCEDURE A.Switch on the Monitor 1.When the power is turned on, The monitor will automatically turn to standby mode. Standby Mode B.Setting Year, Date and Tim 1. Press button ("YEAR" flashes). Press button to adjust YEAR value. 2. Press button ("MONTH"...
Page 24
E.Taking a Measurement 1. Before measurement, press button to select User 1, 2, or 3. User 1 User 2 User 3 | 21 |...
Page 25
2. With the cuff wrapped around your upper arm, press button to start measurement. All display units appear on the screen. Note! Do not inflate the cuff until it is wrapped around your upper arm. 3. After all symbols disappear, the display will show “00”. The monitor is “Ready to Measure”...
Page 26
Note! . If the cuff does not stop inflating, remove the cuff at once. . To stop measurement, press button. The cuff will deflate immediately after the button is pressed. 4. After the monitor has determined your blood pressure and heart rate, the cuff automatically deflates.
MEMORY FUNCTION Storing data After each measurement, the systolic and diastolic pressure, heart rate, pulse, BP Category Indicator, and Irregular Heartbeat Detector symbol (if any) with date and time will be automatically stored. The monitor can store up to 120 memories for 3 users, and automatically replace the oldest data with new one.
Erasing data 1. Press button to select User 1, 2, or 3. 2. Press button to enter Memory Mode. 3. Press and hold buttons at the same time, the data will be erased automatically. 4. To confirm the data in the selected user has been erased, press button and no data should appear.
Page 29
To delete User (1, 2, or 3) memory data or all memory data in the BPM; you can use Bluetooth device which have downloaded the MOCACARE app to complete the deletion. Please download MOCACARE app on Apple App Store or Google Play.
STORAGE AND MAINTENANCE General Use Do not in any way twist the cuff. ● Do not press button if the cuff is not wrapped around your ● upper arm. Do not drop the product and avoid any strong impacts. ● Maintenance To e n s u r e t h a t y o u r d e v i c e i s i n o p t i m a l u s e a n d t o a v o i d d a m a g e , p l e a s e r e f e r t o t h e f o l l o w i n g i n s t r u c t i o n s :...
Page 31
After cleaning / disinfection/ before use, please make sure that ● there are no blood stains or soil on the LCD, the device and cuff, If there is any blood stains or soil, please dispose the device without reuse. If it is used in a complex environment (such as a hospital) or after ●...
LIMITED WARRANTY Warranty For Two Years from the manufacturing date Please also note that this service does not cover damage caused by misuse or abuse; accident; the attachment of any unauthorized a c c e ss o r y ; a l te ra t i o n to t h e p ro d u c t ; i m p ro p e r i n s ta l l a t i o n ; unauthorized repairs or modifications;...
TROUBLESHOOTING SYMBOLS/SYMPTOMS CONDITIONS/CAUSES INDICATION/CORRECTION Replace them with 4 new AAA Worn-out batteries. (1.5V, LR03) alkaline batteries. Unit does not turn on when button is pushed. Battery polarities have been Re-insert the batteries in the positioned incorrectly. correct positions. C u f f h a s b e e n p l a c e d Wrap the cuff properly so that incorrectly.
Page 34
TROUBLESHOOTING SYMBOLS/SYMPTOMS CONDITIONS/CAUSES INDICATION/CORRECTION Please re-pairing the BPM Paring has not been completed. and Bluetooth device with each other. S e e t h e “ t h e B l u e t o o t h Bluetooth function is not turn on. Transmission”...
SPECIFICATIONS Model Number MOCAarm-Black Measurement Method 0 ~ 300 mmHg Rated Range of Cuff Pressure 40 ~ 280 mmHg RateRated Range of Determination 40 ~ 199 Beats/Minute Pressure: ± 3 mmHg Measurement Range of Heart Rate Pulse: ± 5 % Max.
Page 36
SPECIFICATIONS Without any operation for 1 minute, device Sleeping Mode automatically shuts off. 4 AAA (LR03) Alkaline Batteries, Arm Cuff with Accessories Tube, Instruction Manual, Storage Pouch RF Type Bluetooth 4.2 BLE System requirement of the Bluetooth 4.2 for Android 4.3 or above Bluetooth device Bluetooth 4.2 for iOS 7.0 or above The contents of this manual and the specifications of the device covered by this manual are subject to...
To avoid inaccurate results caused by cables and external antennas) should electromagnetic interference be used no closer than 30cm (12 inches) to any part of the MOCAarm, Otherwise, degradation of the performance of this equipment could result. Discard the used product to the recycling...
Page 38
NOTE Device information: Internally powered equipment ● Not suitable for use in presence of flammable anesthetic mixture ● with air or with Oxygen or nitrous oxide Continuous operation with short-time loading ● Manufacturer: HEALTH & LIFE CO., LTD. 9F, No. 186, Jian Yi Road, Zhonghe District23553, New Taipei City, Taiwan www.healthandlife.com.tw | 35 |...
Page 39
NOTE Note! This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Page 40
(2)this device must accept any interference received, including interference that may cause undesired operation. MOCAarm essential performance per IEC 80601-2-30 additional essential performance requirements: 2 0 1 . 1 2 . 1 . 1 0 2 L i m i t s o f t h e e r r o r o f t h e m a n o m e t e r f r o m ●...
APPENDIX Guidance and manufacturer’s declaration – electromagnetic emissions The device is intended for use in the electromagnetic environments listed below, and should only be used in such environments: EMISSIONS TEST COMPLIANCE ELECTROMAGNETIC ENVIRONMENT – GUIDANCE RF e n ergy is us ed o nly to maintain d evic e’s RF emissions operation.
APPENDIX Guidance and manufacturer’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environments listed below, and should only be used in such environments: ELECTROMAGNETIC IMMUNITY IEC 60601 COMPLIANCE ENVIRONMENT – TEST TEST LEVEL LEVEL GUIDANCE In the case of air discharge testing, the climatic conditions Electrostatic...
Page 43
APPENDIX Guidance and manufacturer’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environments listed below, and should only be used in such environments: IMMUNITY IEC 60601 TEST COMPLIANCE ELECTROMAGNETIC TEST LEVEL LEVEL ENVIRONMENT – GUIDANCE P o r t a b l e a n d m o b i l e R F communications equipment 3V rms...
Page 44
APPENDIX Note1 At 80 MHz and 800 MHz, the higher frequency range applies. Note2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
Page 45
APPENDIX Test specifications for enclosure port immunity to RF wireless communications equipment. Test frequency IMMUNITY TEST LEVEL Modulation (MHz) (V/m) Pulse modulation 18 Hz FM ± 5 kHz deviation 1kHz sine Pulse modulation 217 Hz Pulse modulation 18 Hz 1720 1845 Pulse modulation 217 Hz 1970...
BLOOD PRESSURE DIARY Before Date: Time: Meal After Systolic / Diastolic: Pulse: Before Date: Time: Meal After Systolic / Diastolic: Pulse: Before Date: Time: Meal After Systolic / Diastolic: Pulse: Before Date: Time: Meal After Systolic / Diastolic: Pulse: Before Date: Time: Meal...
Page 47
DOWNLOAD MOCACARE APP support@mocacare.com Customer service More information please visit mocacare.com P/N:22290 Rev.A (ATOM) P/N:323103488 VER:001(HL) | 44 |...