Mocacare MOCACuff Series Instruction Manual

Mocacare MOCACuff Series Instruction Manual

Automatic wrist blood pressure monitor

Advertisement

Instruction Manual
| 1 |

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MOCACuff Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mocacare MOCACuff Series

  • Page 1 Instruction Manual | 1 |...
  • Page 2 Automatic Wrist Blood Pressure Monitor Model Number: MOCACuff-Black 04 Medical Disclaimer 23 Positioning Guide 04 Intended Use 24 Measurement Procedure 04 About Blood Pressure 28 Memory Function 06 Measurement Method 30 Bluetooth Transmission 07 Accuracy 32 Storage and Maintenance 07 Precautions 34 Troubleshooting 11 Device Overview 36 Warranty &...
  • Page 3: Medical Disclaimer

    MEDICAL DISCLAIMER The BP Category Indicator will show the and increases from the afternoon to days you can average all the results and This manual and product are not meant information with the readings on the the evening. It is on average lower in this will give you an accurate idea of what as a substitute for advice provided by your screen for the user to track their blood...
  • Page 4: Measurement Method

    inflation automatically starts. The inflation sphygmomanometer, considered the gold of the cuff creates pressure around the standard in blood pressure measurement. arteries inside the wrist. Within the cuff All MOCACuff Automatic Wrist Blood is a gauge which senses the fluctuations Pressure Monitors have performed (oscillations) in pressure.
  • Page 5 a medical problem, promptly consult • Rest at least 5 ~ 10 minutes before * People with arrhythmias your medical history. By using the unit your healthcare provider. taking a measurement. * Undergoing intravenous injection and recording the results regularly for •...
  • Page 6: Device Overview

    * Attention! hemorrhage, or temporary DEVICE OVERVIEW 1. Do not use the device on numbness to your wrist. In Product components infants, children, or those general, these symptoms who cannot express their should not last long. How- own intention. ever, if you do not recover 2.
  • Page 7: Symbol Definitions

    DEVICE OVERVIEW SYMBOL DEFINITIONS Units display Symbols Definitions This symbol appears when the battery power is excessively low or the polarity reverses. We suggest you replace all batteries with new ones, and make LOW BATTERY SYMBOL sure the +/- polarities are properly positioned. Once pulse is detected, the symbol flashes with each pulse beat.
  • Page 8 Symbols Definitions Stages of Blood Systolic Diastolic Recommendations by SIGN 49: Color Pressure Levels (mmHg) (mmHg) Hypertension in older people LCD displays this symbol when Bluetooth Function Confirm immediately and repeat BP in one Grade 3 Severe ≥ 180 ≥ 110 day and again within one week depending Hypertension turns ON.
  • Page 9 the bar indicator which corresponds to pressure for people with diabetes and Irregular Heartbeat Detector medical advice. BP Category Indicator. chronic kidney disease. A blood pressure The symbol will appear on screen 2. As a safeguard, we rec- of 130/80 mmHg or higher is considered indicating a certain heartbeat irregularity ommend that if you have * Note!
  • Page 10 If paired Bluetooth-enabled device is not the operation of other nearby 5. Bluetooth data transmission 1. To install MOCACARE FREE APP, go to the working or is not within RF range of this devices. Additionally, other is not available under mea-...
  • Page 11: Installing Batteries

    INSTALLING BATTERIES 3. Now you can start using your Android version or iOS version of MOCACARE app with Bluetooth feature, it’s a simple tool to log, track and trend your test results from your Bluetooth-enable Device. * Note! MOCACARE app Software Manual...
  • Page 12: Applying The Cuff

    to local regulations. (cadmium) batteries. Do not 2. Keep the battery away mix old and new batteries. from children in case they choke on it. 3. To prolong the battery life 0.4inch and prevent damage caused (10mm) by leakage, remove the batteries from the device if the device is not to be used for a long period.
  • Page 13: Positioning Guide

    Position 1 Position 2 Front Side Front Side MEASUREMENT PROCEDURE • Adjust DATE (1, 2, 3,…, 31), HOUR (1, 2, POSITIONING GUIDE 4. Rest your wrist on the armrest until Switch on the Monitor 3,……..12 PM,1 PM,…,12) and MINUTE It is extremely important that the cuff be it’s at the same height as your heart.
  • Page 14 Bluetooth feature ON Bluetooth feature OFF Turning Bluetooth Feature ON/OFF Get Started to Measure” and will automatically User can press and hold button 3 1. With the cuff wrapped around your inflate to the level that is right for you. seconds to turn the Bluetooth feature wrist, press button to start...
  • Page 15: Memory Function

    MEMORY FUNCTION cuff will deflate immediately measuring results first. after the button is pressed. Storing data 2. Press button again, LCD displays the 3. A After each measurement, the systolic and latest measuring result. Use button 4. LCD screen displays your systolic rate, diastolic pressure, heart rate with date to scroll through all stored measuring diastolic rate, pulse, BP Category Indicator...
  • Page 16: Bluetooth Transmission

    2. While transmitting the reading to your Bluetooth-enabled device, MOCACuff Bluetooth Symbol will remain steady on the screen. 3. MOCACuff can only pair up with one Bluetooth-enabled device at a time. To transmit measuring results to other Bluetooth-enabled device, please retry Steps 1 ~ 2.
  • Page 17: Storage And Maintenance

    Date/Time Synchronization including software upgrades, patches STORAGE AND MAINTENANCE 1. The BPM’s Date/Time Setting can be Maintenance and maintenance. General Use synchronized by Bluetooth-enabled • Use a piece of cloth with water or mild • Do not in any way twist the cuff. device (e.g.
  • Page 18: Troubleshooting

    TROUBLESHOOTING SYMBOLS / SYMPTOMS CONDITIONS / CAUSES INDICATION / CORRECTION SYMBOLS / SYMPTOMS CONDITIONS / CAUSES INDICATION / CORRECTION Replace them with 2 new Worn-out batteries. Please re-pairing the BPM AAA (LR03) alkaline batteries. Paring has not been and Bluetooth device with Unit does not turn on when completed.
  • Page 19: Warranty & Recalibration

    require recalibration regularly. After SPECIFICATIONS WARRANTY & RECALIBRATION 2 years from the manufacturing date, Warranty For Two Years from the we recommend to have your monitor manufacturing date recalibrated at the local distributor or Model Number MOCACuff-Black Please note that this warranty does importer.
  • Page 20 EN ISO 81060-1 Non-invasive sphygmoma- NOTE nometers-Part 1: Requirements and test This blood pressure monitor complies methods for non-automated measurement with the EC Directive (93/42/EEC) and type (partially applied) IEC 80601-2-30 RF Type Bluetooth 4.0 BLE bears the CE mark. This blood pressure Medical electrical equipment—Part 2-30: RF Modulation GFSK...
  • Page 21 Distributed by: does cause harmful interference • CAUTION: near a mobile phone or microwave MOCACARE Corporation to radio or television reception, To assure continued FCC compliance: oven. At least keep a maximum output 887 Federation Way, which can be determined by 1.
  • Page 22 including interference that • 201.12.1.107 Limits of the change in error APPENDIX may cause undesired op- of the blood pressure determination. The eration. laboratory limits of the change in error of the BLOOD PRESSURE DETERMINATION of Guidance and manufacturer’s declaration – electromagnetic emissions * NOTE the AUTOMATED SPHYGMOMANOMETER "Changes or modifications not...
  • Page 23 Recommended separation distances between portable and Guidance and manufacturer’s declaration – electromagnetic immunity mobile RF communication equipment and the device. The device is intended for use in the electromagnetic environments listed below, The device is intended for use in an electromagnetic environment where radiated RF and should only be used in such environments: disturbances are under control.
  • Page 24 Guidance and manufacturer’s declaration – electromagnetic immunity • NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. • NOTE 2 These guidelines may not apply in all situations. Electromagnetic The device is intended for use in the electromagnetic environments listed below, and should only be used in such environments: propagation is affected by absorption and reflection from structures, objects and people.
  • Page 25 Customer service support@mocacare.com More information please visit mocacare.com P/N: 22123 Rev.D (ATOM) P/N: 323103159 VER:001 (HL) | 48 | | 49 |...
  • Page 26 | 50 |...
  • Page 27 | 52 |...

This manual is also suitable for:

Mocacuff-black

Table of Contents