Download Print this page

Installation Precautions; Application Environment; User Notes - HAISEN HD06VCRH 3 Instruction Manual

Advertisement

Attention
1. Please read the instructions carefully before using this product and keep it well
for all users to read at any time.
2. The sensor should be installed by qualified electrician and ensure power is off
before the installation.
3. We reserve the right to modify any incorrect text, image and necessary technical
parameters.
4. Any unauthorized modification is forbidden, otherwise all guarantees will be
immediately invalid.

Installation precautions

1. Microwave sensor can be installed in any lamp except the one with full metal shell.
2. The detected surface cannot be shielded by metal objects.
3. Make sure the microwave module is completely exposed outside.
4. The detection surface of the sensor module shall be installed facing the detection area.
5. Should be kept away from the driver to avoid interference generation and lamp flashing.
6. Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.

Application Environment

1. Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or
tree swing.
2. Shall not be installed in the place with all four metal shelters and small space (such as
galvanized-iron roof ).
3. Shall note be mounted installation, so as to avoid false trigger caused by the lamp itself shaking.
4. Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false
triggering caused by machine vibration.

User Notes

1.Microwave can penetrate walls or glass thinner than 20cm and attenuate if thicker than 20cm.
2. The driver voltage shall be stable and float within 10%.
3. Detection area will be affected by speed of motion, mounting height and movement volume.
4. Conduct test on sunny days without the lampshade which will affect the tested lux value.
Remote for dimmable sensors
with memory function
HD03R
Shenzhen Haisen Technology Co., Ltd., Tel: +86-755-82598105 丨Fax: +86-755-82598106丨Email: info@haisensz.com 丨www.haisensz.com
ON/OFF
1. "ON/OFF" key only functions as a switch of the light.
2. If press this button to turn off the lamp before it's short-circuited, the lamp will remain off after power-on again.
Auto Mode
Press "Auto Mode" button, the sensor starts to work and all settings remain the same before the light gets switched on/off.
Reset
1、Press "Reset" button, change brightness to max level.
2、Press "Reset" button, products with DIP switch will be controlled by DIP switches; otherwise all the setting will be just
initial, that is 100% detection range,hold time 5S, no stand-by time and daylight threshold disabled.
Flick after press any button
Flick only after press "Apply" button
+/-
1. To adjust brightness 10-100% in on/off mode.
2. To adjust highest brightenss 60-100% in sensor mode.
Start
Press "Start" to customize scene, users can change detection range, daylight threshold, holdtime, standby dimming level and
standby period.
Memory
1. Press "Memory" to save all the settings.
2. The settings remained as the last time if not get resetted values.
Apply
1. Press "Apply" to deliver the saved setting.
2. Press "Apply" without "memory"will make all the setting one-time operation.
3. Settings should be done within 30S, otherwise it exits memory mode.
Detection area (Press to define detection area 100%/75%/50%/25%.)
Hold time (Press to define holdtime 5s/30s/1min/3min /5min/10min/20min/30min .)
Stand-by dimming level (Press to define stand-by dimming level 10%/20%/30%/50%.)
Stand-by period (Press to define stand-by period 0s/10s/30s/1min/5min/10min/30min/+ ∞ .)
Note: "0s" means no standby period; "+∞ " means unlimited standby period.
Daylight threshold (Press to define daylight level 2Lux/10Lux/30Lux/50Lux/80Lux/120Lux/Disable.)
Note: Disable means light will be turned on once sensor detects movement, regardless of the ambient lux.
Test (2s)
The button "Test (2s)" is for testing purpose after commissioning.Pressing this button, the sensor goes to test mode
( hold time is only 2s )