Advertisement

Quick Links

MANUAL FOR INSTALLATION, USE AND
MAINTENANCE
LOFT
Congratulations!
You have chosen an appliance of the Jidé range and we would like to thank you for it. We
are convinced that it will bring you warmth and comfort. In order to derive the greatest
benefit from your fireplace, we greatly stress the importance of following the instructions
and recommendations given in this notice.
Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 –
www.jide.be
-
info@jide.be
LOFT (EN) June 2019

Advertisement

Table of Contents
loading

Summary of Contents for Jide LOFT 56

  • Page 1 Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) June 2019...
  • Page 2: Table Of Contents

    DECLARATION OF CONFORMITY JIDÉ ................20 WARRANTY ........................21 Warranty agreement ........................... 21 Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 3: Introduction

    A list of our dealers-installers is available on our site www.jide.be/en. Before using your fireplace for the first time and in order to guarantee its good usage and operation over time, we suggest you carefully read these instructions for use in order to familiarise yourself with its various functions and characteristics.
  • Page 4: Technical Characteristics And Compliance

    European EN standards on safety and efficiency while limiting CO emissions. Test results according to the standards: EN 13229:2001 - EN 13229/A1:2003 – EN 13229/A2:2004 Loft 56 Loft 77 Nominal power: 8-10 kw Nominal power: 8-12 kw...
  • Page 5: Additional Parts - Identification Plate

    (traceability) if necessary. We advise you to paste it on this user and installation notice or on your invoice. Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 6: User Notice

    For a good performance do not remove completely the ashes of the stove. Do not use inflammable liquid products. Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 7: Combustion

    In this last case, it is essential to seek the advice of your approved installer. Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 8 NEVER use flammable liquid products to light the fire or reactivate the fire! Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 9: The Wood - Choice And Usage

    Birch ....................300 – 400 kg per m³ Poplar ....................250 – 350 kg per m³ Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 10 Loading of the fireplace with wood: Loft 56..............2,5 kg (maximum) of dry wood per hour Loft 77..............2,9 kg (maximum) of dry wood per hour WARNING *************************************************************************** The overloading of wood of your stove may have some consequences and the damage hereafter will obviously not be covered by the warranty;...
  • Page 11: Installation Notice

    The convection air intake under the fireplace must not be obstructed. Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 12: Radiation From The Fireplace

    The chimney must have a normal pulling i.e. that with its power maximum, the depression will have to range between 12 and 20 Pa. Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 13: Installation Of The Chimney Connection

    Your appliance has 2 hot air openings for the convection Remove the disk Fix the duct with three self-boring screws Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 14: Ventilation (Option)

    The fan power is 73 W. Loft 56 – 77 Please leave enough slack on the power cable to remove the fan from inside the unit for...
  • Page 15: Fitting Of The Finishing Frame (Option)

    Cleaning – Chimney sweeping APPLIANCE MAINTENANCE Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 16: Maintenance

    Your dealer will be able to do this. Eccentric for door Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 17: Cleaning The Fan (Option)

    Rotate the fan towards you. Remove the fan from the unit. Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 18: Troubleshooting

    - Negligence with the sweeping - Respect the normal frequency of the sweeping Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 19 - Sanding and repainting - Respect the maximum loading of wood per hour Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 20: Declaration Of Conformity Jidé

    According to the test report issued by the A.R.G.B. laboratories (Royal association of Belgian gas- fitters) meeting the European EN 13229/A2 standard, it was stated that: The power in kW for: Loft 56: ..........................8 to 10 kW Loft 77: ..........................8 to 12 KW Efficiency measured and calculated according to standard is 82%.
  • Page 21: Warranty

    Intentional and permanent interruption of the ventilation;  Usage with the door of the ash box open. Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) September 2019...
  • Page 22 Address ………………………………………………………..………………………… Postcode …………… City ………………………..……………………………. Seller's stamp Stick your identification plate here Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) June 2019...
  • Page 23 ............................................................……………………………………………………………………………………………………………………………………………............................................................……………………………………………………………………………………………………………………………………………............................................................……………………………………………………………………………………………………………………………………………............................... ……………………………………………………………………………………………………………………………………………............................... Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) June 2019...
  • Page 24 Jidé s.a. – Rue des Meuneries 11 – B-4650 HERVE (Belgique) – Tél. +32 87 31.75.12 – Fax +32 87 31.75.11 – www.jide.be info@jide.be LOFT (EN) June 2019...