Fig. 9 - 38UQZ 016-024
PLAN VIEW
The air enters through three sides and is discharged
through the top.
Table 4 - Minimum clearances between units (mm)
38UQZ
A
016-024
500
Return air
Return air
B
C
700
500
Fig. 10 - 38UQZ 016-024
PLAN VIEW
The air enters through three sides and is discharged
through the top.
Table 5 - Minimum clearances between units (mm)
38UQZ
A
016-024
500
Installation on the ground
38UQZ units can be positioned on the floor of a patio,
on the ground or on a lawn. If installed on the ground
or on the lawn they should be mounted on a 100 mm
high concrete base that is 100 mm larger than the base
unit on all four sides.
Return air
Return air
Return air
Return air
B
C
700
500