Combination Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. Top Bottle
Filling section offer touchless activation to dispense water for bottles. While the bottom Water Cooler section, which houses the refrigeration
and filtration systems, delivers a steady stream of water for direct drinking.
Ratings
• Electrical: 220-240 Vac, 50/60 Hz, (See Nameplate for Amperage),
1 phase
• Ambient Air Temperature: 50-89.6 °F (10-32 °C)
• Water Pressure: 20-105 psig (0.14-0.72 MPa)
• Maximum Water Temperature: 90 °F (32 °C)
• Sound Pressure level (A-weighted): < 70 dBA
Definitions
DANGER
– Indicates death or serious injury will result if proper precautions are not taken.
WARNING
– Indicates death, serious injury or property damage can result if proper precautions are not taken.
CAUTION
– Indicates some injury or property damage may result if proper precautions are not taken.
Authorized Service Personnel – Factory trained personnel or personnel having working knowledge of electrical, plumbing and
machine (appliance) maintenance procedures. Service personnel must have specialized training for flammable refrigerants.
Safety
DANGER
• Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions
and safety precautions in this manual can result in serious injury or death.
• After installation, keep these instructions in a safe location for future reference.
• Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.
• Electrical supply may require Ground Fault Circuit Interrupter (GFCI) protection. Consult specific application and local codes.
• A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to
allow electrical disconnection of the unit from electrical supply after installation.
WARNING
• Keep clear of obstructing all ventilation openings in the appliance enclosure or in the structure for building-in.
• Place in a well ventilated area to prevent accumulation of refrigerant.
• No open flame or sparks during service or repair.
• For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before the system.
• Installation and connection to water and electrical mains must be in compliance with local and national laws.
• All Installation and Service work must be performed by trained / authorized service personnel.
Notice: Coolers that use flammable refrigerants, such as R-600a (isobutane), R-290 (propane) will be marked with a
specific symbol that notifies the servicer of the presence of these refrigerants. A service provider should review this marking
and follow all instructions from the original equipment manufacturer.
LZFS8WSN_2AWR
Installation & Use Manual
Original Instructions
• Refrigerant: R290
• Ingress Protection: IP20
• For Indoor Commercial Use only
• Water Inlet: 3/8"O.D. unplated copper tube
• Waste Water Outlet: 1-1/4" O.D. tube
Page 1
2000000554 (Rev. B - 06/22)

Advertisement

loading

Summary of Contents for Elkay LZO8WSS2KWN

  • Page 1 LZFS8WSN_2AWR Installation & Use Manual Original Instructions Model: LZO8WSS2KWN Bottle Filling Station & Cooler Description Combination Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. Top Bottle Filling section offer touchless activation to dispense water for bottles. While the bottom Water Cooler section, which houses the refrigeration and filtration systems, delivers a steady stream of water for direct drinking.
  • Page 2: Installation: Electrical Connection

    LZFS8WSN_2AWR CAUTION • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 3 LZFS8WSN_2AWR Rough-In: LZO8WSS2KWN 17-7/8” (454mm) 7” 7” (178mm) (178mm) 7/16” x 3/4” OBROUND 3-9/16” (11mm x 19mm) HOLES (6) (90mm) 6-3/8” 6-3/8” 18-7/8” ACTIVATION (162mm) (162mm) (479mm) 15” SENSOR (381mm) 19” (483mm) 9/32” O HOLES HANGER BRACKET (7mm) (12) 2-7/8”...
  • Page 4: Operation: Start-Up

    LZFS8WSN_2AWR 9. With the power cord and waterline through hole on top of water cooler, place Bottle Filler on the three (3) angled tabs protruding from the wall mounting plate, installed on wall (See Fig. 6). Make sure round WALL MOUNTING PLATE boss in gasket fits in hole of basin.
  • Page 5 LZFS8WSN_2AWR Operation: Bottle Filler Control Board Set-Up VERIFY CONTROL BOARD SOFTWARE “UNIT TYP” - Type of unit (REFRIG or NON-RFRG) 1) To verify the software program of the control board the unit will “FLT SIZE” - Select filter capacity need to be shut down and restarted. The chiller (if present) does “RST BCNT”...
  • Page 6: Service Adjustments

    LZFS8WSN_2AWR Service For proper and safe servicing, please read these instructions completely. DANGER All Service and Maintenance must be performed by an authorized service person. Service Technician must have specialized training before servicing systems containing flammable refrigerants. Personnel who have not received certification for completing the Hydrocarbon Training Program and passed the examination, or received equivalent training and certification, do not service any system containing flammable refrigerants.
  • Page 7 LZFS8WSN_2AWR Service: Inspection/Replacement • Inspect Bottle Filler and Cooler twice each year for proper operation and performance. • Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices. 1. Lower Front Panel and Upper Shroud: To access the refrigeration system and plumbing connections, remove four (4) screws from bottom of cooler to remove the lower front shroud.
  • Page 8 ASSY - FIilter Head & Bracket (LZ) For Replacement Parts, contact your local distributor or call 1.800.834.4816 Elkay Manufacturing Co. 1333 Butterfield Road Suite 200 Downers Grove, IL 60515 U.S.A – 630.574.8484 – www.elkay.com 2000000554 (Rev. B - 06/22) Page 8...