Dear Customer, Technical Data ....6 Thank you for choosing a GROHE product. Please follow these instructions carefully Installation ..... . . 7 and you will enjoy many years of reliable Exposed Installation.
- Installation with reversed supplies New Water Regulations possible by rotating the cartridge 180° This GROHE-product is designed to comply with the current Water Bylaw 17 and the new Water Regulations covering back-flow pre- vention. It must be installed in accordance with local authority bye-laws.
Installation Exposed Installation 3.Place the valve body (B) with the elbows and backplate (A) to the supply pipes, see The standard position is outlet to bottom. Fig. [2]. The Pressure Balance Valve is fixed to the wall via the backplate and connected to the supply pipes by a pair of elbows.
Page 7
Installation 7.Fix the backplate (A) with the fillet (A1) 10. Tighten the compression nuts (torque down to the wall with screws (D), see min. 20 Nm), see Fig. [7]. Fig. [5]. 8.Slide the valve body with elbows and com- 11. Slide the chassis (G) with the interme- pression nuts loosely over the supply diate handle (H) over the driver (J) and pipes, see Fig.
Page 8
Installation 12. Thread the connection nipple (K) with 15. Push adjustable hot water limit stop (N) the O-ring seal and the stops into the to the intermediate handle (H) as de- valve body outlet, see Fig. [9]. scribed in Fig. [11]. Please refer to chapter "Maximum Hot Water Limit Setting"...
Page 9
Installation Reversed Supplies Installation 7.Loosen screw (J1) and pull off driver (J). 8.Detach stop ring (R) and note position. For reversed supplies installation the 9.Remove the four corner screws (S1) and cartridge must be rotated 180° to ensure valve cover (S). proper valve operation.
Page 10
Installation Maximum Hot Water Limit Setting 4.Place the hot water limit stop (N) over the splines on the intermediate handle with the On applications requiring limiting the valve limit stop resting against the chassis stop opening from full hot position, the adjustable post, see Fig.
6.Remove screws (G1) and chassis (G), 1.Remove the connection nipple (K), see see Fig. [19]. Fig. [18]. 2.Detach retaining ring (K1). 3.Pull out non-return valves. Check, clean and if necessary replace parts. Only genuine GROHE replacement parts must be used.
Care We want to ensure that you get long-lasting mulations of commercially available cleaning satisfaction and pleasure from your GROHE agents frequently change, we cannot gua- fitting. Therefore, please read the following rantee they will provide the gentle care our care instructions because damage to the fitting deserves.