Technical Specifications - BEA LZR-S600 User Manual

Laser scanner for building automation & security
Hide thumbs Also See for LZR-S600:
Table of Contents

Advertisement

TECHNICAL SPECIFICATIONS

Technology:
Detection mode:
Detection range:
Angular resolution:
Min. detected object size (typ.):
Emission characteristics
IR laser:
Red visible laser:
Supply voltage:
Power consumption:
Peak current @ power-on:
Cable length:
Response time:
Output:
Max. switching voltage:
Max. switching current:
Switching time:
Output resistance:
Voltage drop on output:
Leakage current:
Input:
Max. contact voltage:
Voltage threshold:
Response time monitoring input:
LED signal:
Dimensions:
Material:
Color:
Mounting angles on bracket:
Rotation angles on bracket:
Tilt angles on bracket:
Protection degree:
Temperature range:
Humidity:
Vibrations:
Pollution on front screen:
Norm conformity:
Specifications are subject to change without prior notice. All values measured in specific conditions.
75.5792.08 LZR-S600 20220429
LASER scanner, Time-of-Flight measurement
motion and presence
Default: 33' x 33' @ 2% remission factor (max. 82 ft x 82 ft)
0.3516°
0.8 in @ 10 ft
1.4 in @ 16 ft
2.8 in @ 33 ft
6.9 in @ 82 ft
wavelength 905 nm; output power 0.10mW (CLASS 1)
wavelength 635 nm; output power 0.95mW (CLASS 2)
10 – 35 VDC @ sensor side
< 5 W
1.8 A (max. 80 ms @ 35 V)
33'
typ. 20 ms (max. 80 ms)
+ output activation delay
2 electronic relays (galvanic-isolated – polarity-free)
35 VDC / 24 VAC
80 mA (resistive)
t
= 5 ms; t
= 5 ms
ON
OFF
typ 30 Ω
< 0.7 V @ 20 mA
< 10 µA
2 optocouplers (galvanic-isolated – polarity-free)
30 VDC (over-voltage protected)
Log. Active High: > 8 VDC
< 5 ms
1 blue LED: power-on status
1 orange LED: error status
2 bi-colored LEDs: detection/output status (green = no detection, red = detection)
3
5
"× 2
3
"× 5" (W × H × D)
8
4
PC/ASA
Black
-45°, 0°, 45°
-5 – 5° (lockable)
-3 – 3°
NEMA 4 / IP65
powered: -22 – 140 °F (-30 – 60 ºC)
0 – 95% non-condensing
< 2G
max. 30%, homogenous
2006/95/EC: LVD
2004/108/EC: EMC
2002/95/EC: RoHS
IEC 60529:2001
Log. Active Low: < 3 VDC
mounting bracket: +
1
"
2
unpowered: 14 – 140 °F (-10 – 60 ºC)
IEC 60825-1:2007
IEC 60950-1:2005
IEC 61000-6-2:2005
IEC 61000-6-3:2006
Page 11 of 12