6.6
Power ON
• A push-button is available on the bottom of enclosure.
• The RESET button must be pressed during 1s to generate a SW reset of the product.
• Note that a long press for 5s halts the gateway.
Once the power is "On", please check the LED status and start the SW configuration.
The iStation should power on, showing:
• a solid green LED (Power LED, under the power button),
• accompanied by a red LED (Status LED =operations status) starting solid, then blinking during bootup.
Gateway status
Boot part 1
Boot part 2
Boot part 3
Run time
Power down sequence
Restore backup
Restore stock
For more information on the « Quick start of Wirnet™ iStation Gateway, please consult the Kerlink Wiki:
http://wikikerlink.fr/wirnet-productline/doku.php?id=wiki:quickstart:quickstart_istation
6.7

First connection

The Wirnet productline embeds a web interface to allow to easily manage the gateways:
• Trigger software upgrade/update,
• Configure the backhaul connectivity,
• Trigger actions on the gateway: Turn-off, reboot, factory reset ...
The generic syntax to access to this web interface is: http://klk-<type_GW>-<serial>/
This means: for the Wirnet iStation: http://klk-wiis-03002e/
Note that if your computer is on the same local network, you can also use directly the IP address of your
gateway in a browser to connect to the Web interface.
The default credentials are available on the wiki.
For security reasons, it is strongly recommended to change the default passwords.
«Status LED» behaviour
Fix on
Heart beat
Blink every second
Off
Heartbeat
Blink / 2 seconds
Blink / 4 seconds