Step
Preset to
Adjustment
Remarks
9
Mode: CW
No
Check if the RF power level is 23
rv
29 W reading on the RF
KEYSW: ON
alignment
power meter.
Mode: CW
10
(Low Power)
No
Check if the RF power level is 3
rv
7 W reading on the RF
Pull RF Gain Con-
alignment power meter.
trol
4. TEST EQUIPMENT CONNECTION
CW KEY SW
~
SSVM
Oscilloscope
+TP6
DC
0
0
000
Oscilloscope
Spectrum
Analyze
r
Connection for Transmitter Alignment
MIC PLUG
-13-
TX SW
::----c/o
:
AFOSC(+)
AFOSC(-)