Altimeter - Casio MO0804-EA Operation Manual

Casio watch user manual
Table of Contents

Advertisement

• Temperature is displayed in units of 0.1°C (or 0.2°F).
• The displayed temperature value changes to
temperature falls outside the range of –10.0°C to 60.0°C (14.0°F to
140.0°F). The temperature value will reappear as soon as the measured
temperature is within the allowable range.
• In some areas, barometric pressure is expressed in millibars (mb) instead
of hectopascals (hPa). It really makes no difference, because 1hPa = 1mb.
• You can select either hectopascals (hPa) or inchesHg (inHg) as the display
unit for the measured barometric pressure, and Celsius (°C) or Fahrenheit
(°F) as the display unit for the measured temperature value. See "To select
the temperature, altitude, and barometric pressure units".
• See "Barometer and Thermometer Precautions" for important precautions.
Barometric Pressure Graph
Barometric pressure indicates changes in the atmosphere. By monitoring
these changes you can predict the weather with reasonable accuracy.
This watch takes barometric pressure measurements automatically every two
hours (at the top of each even-numbered hour), regardless of its current
mode. Measurement results are used to produce barometric pressure graph
and barometric pressure differential pointer readings.
The barometric pressure graph shows readings of previous measurements for
up to 24 hours. The horizontal axis of the graph represents time, with each dot
standing for two hours. The rightmost dot represents the most recent reading.
The vertical axis of the graph represents barometric pressure, with each dot
standing for the relative difference between its reading and that of the dots
next to it. Each dot represents 1hPa.
The following shows how to interpret the data that appears on the barometric
pressure graph.
A rising graph generally means improving weather.
A falling graph generally means deteriorating weather.
Note that if there are sudden changes in barometric
pressure or temperature, the graph line of past
measurements may run off the top or bottom of the display.
The entire graph will become visible once barometric
conditions stabilize.
The following conditions cause the barometric pressure
measurement to be skipped, with the corresponding point on
the barometric pressure graph being left blank.
• Barometric reading that is out of range (260 hPa/mb to 1,100 hPa/mb or
7.65 inHg to 32.45 inHg)
• Sensor malfunction
Barometric Pressure Differential Pointer
This pointer indicates the relative difference between the most recent
barometric pressure reading indicated on the barometric pressure graph, and
the current barometric pressure value displayed in the Barometer/
Thermometer Mode.
• Pressure differential is indicated in the range of ±5 hPa, in 1-hPa units.
• The barometric pressure differential pointer is not displayed when the
displayed current barometric value is outside of the allowable measurement
range (260 to 1,100 hPa).
• Barometric pressure is calculated and displayed using hPa as the standard.
The barometric pressure differential also can be read in inHg units as
shown in the illustration.
inHg values
hPa values
Barometric pressure
differential
Pressure differential
examples in the
illustration are indicated
in 3 hPa/0.1 inHg steps.
About Barometric and Temperature Measurements
• Barometric pressure and temperature measurement operations are
performed as soon as you enter the Barometer/Thermometer Mode. After
that, barometric pressure and temperature measurements are taken every
five seconds.
• You also can perform a barometric pressure and temperature measurement
at any time by pressing B in the Barometer/Thermometer Mode.
Operation Guide 3143
°C (or °F) if a measured
xxx
Not visible on
the display.
Current pressure greater
than most recent
measured pressure
Current pressure less
than most recent
measured pressure

Altimeter

The watch's altimeter uses a pressure sensor to detect current air pressure,
which is then used to estimate the current altitude based on ISA (International
Standard Atmosphere) preset values. You also can specify a reference
altitude, which the watch will use to calculate your current altitude based on
the value you specify. Altimeter functions also include storage of
measurement data in memory.
You also can measure the altitude differential (change) from a specific
reference altitude. Specifying the reference altitude is as simple as pressing a
single button to reset the reference altitude to zero.
Important!
• This watch estimates altitude based on air pressure. This means that
altitude readings for the same location may vary if air pressure changes.
• The semiconductor pressure sensor used by the watch for altitude
measurements also is affected by temperature. When taking altitude
measurements, make sure the watch is not subjected to temperature
changes.
• To avoid the effect of sudden temperature changes during measurement,
keep the watch on your wrist in direct contact with your skin.
• Do not rely upon this watch for altitude measurements or perform button
operations while sky diving, hang gliding, or paragliding, while riding a
gyrocopter, glider, or any other aircraft, or while engaging in any other
activity where there is the chance of sudden altitude changes.
• Do not use this watch for measuring altitude in applications that demand
professional or industrial level precision.
• Remember that the air inside of a commercial aircraft is pressurized.
Because of this, the readings produced by this watch will not match the
altitude readings announced or indicated the flight crew.
How the Altimeter Measures Altitude
The altimeter can measure altitude based on its own preset values, or a
reference altitude specified by you.
When you measure altitude based on preset values
Data produced by the watch's barometric pressure sensor is converted to
approximate altitude based on ISA (International Standard Atmosphere)
conversion values stored in watch memory.
When you measure altitude using a reference altitude specified by you
After you specify a reference altitude, the watch uses that value to convert the
current measured barometric pressure value to altitude.
• When mountain climbing, you can set the
reference value in accordance with a marker
along the way or altitude information from a
map. After that, the altitude readings
produced by the watch will be more accurate
than they would without a reference altitude.
Displaying Your Current Altitude
You can use the procedure described in this section to display your current
altitude. If you leave the watch in the Altimeter Mode, it will update the
displayed altitude value regularly, and indicate reading-to-reading changes in
the altitude graph at the top of the display.
The Altimeter Mode gives you a choice of four different display formats. The
format you choose determines what type of data is displayed. The Altimeter
Mode screen can show any three of the following four items: altitude graph,
altitude value, altitude differential, and the current time. You also can select
either of the following two altitude measurement types.
0'05: Readings at five-second intervals for one hour
2'00: Readings at five-second intervals for the first three minutes followed
by two-minute intervals for approximately nine or 10 hours
• For information about configuring settings for the altitude reading interval
and duration, see "To select the altitude measurement type".
Important!
• The procedure in this section simply displays values indicating your current
altitude, without storing them in watch memory. For information about
recording altitude readings in watch memory, see "Saving Altitude Data".
To display your current altitude
1. Press D in the Timekeeping Mode or
Altitude graph
Barometer/Thermometer Mode to enter the
Current altitude
Altimeter Mode.
• The watch will start altitude measurement
automatically, and display the result.
• It can take up to four or five seconds for the
altitude reading to appear after you enter
the Altimeter Mode.
2. If you want the altitude value and altitude
graph to be updated in accordance with the
Current time
altitude measurement type (interval and
Altitude differential
duration) you have selected, leave the watch
pointer
in the Altimeter Mode.
• If you want to restart the altitude measurement
operation at any point, press D.
3. To stop the altitude measurement operation,
press C to exit the Altimeter Mode.
B
A
400
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3143

Table of Contents