Settings - golmar iPG+ CE-ART 7/G+ Installer Manual

Table of Contents

Advertisement

CE-ART 7/G+
Once you have accessed the guard unit Web Client, a screen will appear in which you will be able to configure the device.
On the left hand of the screen, you can fill in the
fields related to:
Language: You can choose between Spanish,
English and Portuguese.
Dialing code
length: 5 or 6 depending if a
distinction is to be made as to floor number.
Block
number: Number of block in which the
guard unit is located. If it is a general guard unit
you must set the block number as 99.
Apartment
address: Guard units have reserved
addreses from
851
In case of a
general guard
901
addresses go from
To end the configuration, press the "Apply" button to save the parameters set. The guard unit will reboot and the initial configuration
will be done.

6. SETTINGS

Settings.
The settings section provides the following options:
In this manual we will focus on the "System" settings as the other sections are described in the user manual of the CE-ART 7/G+ guard
unit.
First of all, to access the system settings section it is necessary to enter a password.
NOTE: For more information about the guard unit settings, visit the user manual.
7
On the right side of the screen, it appear the fields related to the IP addresses. You can
manually assign the IP address to the guard unit in the same way as describe before.
until
859
for each block.
unit, the reserved
to 919.
Password
Sistema
Enter password
The factory default password is
APARTMENT UNIT
Network
Language *
1
Dialing code length
5
Automa�c se�ngs
Block number
1
Local IP
Apartment address
Subnet Mask
1
Gateway
Server IP
*Languages
1 Spanish
2 English
3 Portuguese
Personal
Alarmas
1
2
3
4
5
6
7
8
9
0
2718.
IP G+
Se�ngs
Sip Server
10.0.7.105
255.0.0.0
About
10.0.0.1
10.0.14.9
Sistema
www.golmar.es