CE-ART 7/G+

4. INITIAL CONFIGURATION

Once the guard unit is installed, you will do its initial configuration. As mentioned above, this device does not require of a computer or
specific knowledge about networks for its installation and further programming.When you have connected the device to the network,
this will turn on automatically and the
of the guard unit:
Initial config
Language
Dialing code length
Block number
Apartment address
Once you have entered the desired parameters, press
the "save" icon. The guard unit will be configured
and it will reboot. The system will assign it a default
IP address.
In the case of the user wants to set a determined IP address, press the icon
Network settings
L
Automatic
Local IP
Subnet Mask
Gateway
Server IP
Once entered all required data, press
5
"Initial configuration"
screen will appear. The following shows how to do the initial configuration
English
Español
Português
1
1
1
to save the configuration. The guard unit will reboot.
On this screen, you must configure the guard unit by setting
up the:
Language: You will be able to choose between Spanish,
English and Portuguese.
Dialing code
length: 5 or 6 depending if a distinction is to
be made as to floor number.
Block
number: Number of block in which the guard unit
is located. If it is a
general guard
block number as 99.
Apartment
address: Guard units have reserved addreses
851
859
from
until
for each block. In case of a
guard
unit, the reserved addresses go from
and the next screen will appear:
Then, having enabled the manual entering pressing
must fill in the fields with the corresponding data:
Local
IP: Ip address which you want to assign to the guard
unit.
Subnet
mask: Guard unit subnet mask.
Gateway: Determined gateway address.
IP
Server: Server IP address. Remember that in the
installation, the master panel or management panel is
which do the server functions. Therefore, we will enter the
management panel IP address
field.
IP G+
unitl, you must set the
general
901
to 919.
, you
of the installation in this
www.golmar.es