SETTING FOR OPERATION

The RM620 movement detector can be configured in mono direction mode (one direction
only) or in bi directional mode (in both directions).
Remove the rubber plug from the lower section of the detector (Fig. 1-A) and set the
required function through the dip-switch (Fig. 1-B), choosing from the possibilities
indicated in the table:
DSW1 DSW2 DSW4
OFF
-
ON
OFF
-
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
ASSEMBLY AND ORIENTATION
RM620 can be installed at the centre of the door to be controlled or on the side, on non-
vibrating structures (walls or ceiling) and at a maximum height of 6 m. Use the template
supplied to prepare the holes.
Fasten the device using the prepared holes, remove the lower cover (Fig. 2-A) and
loosen the screw that blocks the detector orientation. Direct the detector toward the area
to be controlled and lock in that position.
For correct operation, do not install RM620 :
- facing the moving parts of the door
- facing fluorescent lights (minimum distance 2m)
- facing areas where rain could provoke water fluxes
These conditions could activate the device and cause the unwanted opening of the door.

ELECTRICAL CONNECTIONS

Connect the pre-wired cable as indicated in table 1 then power the detector.
6
6
SENSITIVITY
CONDITION
Low
Movement is detected in both directions
High
Movement is detected in both directions
Low
Approach to the sensor is detected
High
Approach to the sensor is detected
Low
Movement away from the sensor is detected
High
Movement away from the sensor is detected
www.abtecno.com
ENGLISH
www.aperioaccess.it