Download Print this page
PHYWE Cobra SMARTsense Radioactivity 12937-01 Quick Start Manual

PHYWE Cobra SMARTsense Radioactivity 12937-01 Quick Start Manual

Advertisement

Quick Links

PHYWE Systeme GmbH & Co. KG
Robert-Bosch-Breite 10
D–37079 Göttingen
+49 (0) 551 604–0
Telefon
+49 (0) 551 604–107
Fax
E-mail
info@phywe.de
Internet
www.phywe.com
Operating
instructions
The unit complies
with the applicable
EC-guidelines
TABLE OF CONTENTS
1
SAFETY PRECAUTIONS
2
PURPOSE AND CHARACTERISTICS
3
FUNCTIONAL AND OPERATING ELEMENTS
4
NOTES ON OPERATION
5
HANDLING
6
TECHNICAL DATA
7
SCOPE OF DELIVERY
8
ACCESSORIES
9
CONFORMITY
10 DISPOSAL
www.phywe.com, © All rights reserved
Cobra SMARTsense Radioactivity
Fig. 1: 12937-01 Cobra SMARTsense Radioactivity
1
SAFETY PRECAUTIONS
Caution!
Carefully read these operating instructions completely
before operating this instrument. This is necessary to
avoid damage to it, as well as for user-safety.
Only use the instrument for the purpose for which it was
designed.
Only use the instrument in dry rooms in which there is no
risk of explosion.
Protect the instrument from dust, moisture and vapours.
Use a slightly moist lint-free cloth to clean the instrument.
Do not use aggressive cleaning agents or solvents.
Take care that no liquid penetrates in through the hous-
ing openings, as such penetration would result in dam-
age to Sensor.
Do not open the unit.
2
PURPOSE AND CHARACTERISTICS
The sensor is used for measuring the respiratory volume and
volumetric flow rate and for transferring the values to a termi-
nal device, e.g. a tablet computer, smartphone, etc., via Blue-
tooth or USB.
The sensor is neither suitable nor approved for medical pur-
poses. It is intended solely for didactic purposes. This device
must not be used for defined measurements on humans in
order to diagnose an illness or disease, i.e. it is not intended
for monitoring, treating or alleviating illnesses or diseases. As
a consequence, it is not subject to the strict constraints of the
Medical Devices Act.
12937-01
1
12937-01 / 2621

Advertisement

loading
Need help?

Need help?

Do you have a question about the Cobra SMARTsense Radioactivity 12937-01 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PHYWE Cobra SMARTsense Radioactivity 12937-01

  • Page 1 Cobra SMARTsense Radioactivity 12937-01 PHYWE Systeme GmbH & Co. KG Robert-Bosch-Breite 10 D–37079 Göttingen +49 (0) 551 604–0 Telefon +49 (0) 551 604–107 E-mail info@phywe.de Internet www.phywe.com Operating instructions The unit complies with the applicable EC-guidelines Fig. 1: 12937-01 Cobra SMARTsense Radioactivity TABLE OF CONTENTS SAFETY PRECAUTIONS...
  • Page 2 If the sensor is to be used via the USB interface, it does not need to be switched on. The sensor is connected directly to the end device using the supplied USB cable. www.phywe.com, © All rights reserved 12937-01 / 2621...
  • Page 3 TECHNICAL DATA PHYWE Systeme GmbH & Co. KG Abteilung Kundendienst Operating temperature range: 5 - 40°C Robert-Bosch-Breite 10 Rel. humidity < 80% D–37079 Göttingen 0 … 40000 #/min Range Telefon +49 (0) 551 604-274 Resolution 1 #/min +49 (0) 551 604-246 Max. date rate 10 Hz Max.