  • Page 1 PULL LINE BLOWER OPERATING INSTRUCTIONS...
  • Page 2 Dear Customer Thank you for choosing a quality engineered ZEITLER product. Our machines are built using modern production techniques and comprehensive quality assurance. Every effort has been made to ensure your satisfaction and trouble-free use of the machine.
  • Page 3: Table Of Contents

    Contents Guide to Using the Operating Instructions Safety Precautions and Working Techniques Scope of supply EZ300 Optional Accessories and Expendable Materials Special Pull line Shuttle Assembling How to Use Accessories Blowing mode with EZ300 Suction Mode with EZ300 10. Fuel 11.
  • Page 4: Guide To Using The Operating Instructions

    Caution where there is a risk of damaging the machine or its individual components. Engineering improvement ZEITLER’s philosophy is to continually improve all of their products. For this reason, we may modify the design, engineering and appearance of our products periodically.
  • Page 5 Blowing pull line into cable conduits (ø 25-200 mm) Do not operate the power tool if you are under the influence of any substance (alcohol, drugs) which might impair visions, dexterity of judgement. Applications The EZ300 Pull Line Blower is intended exclusively for blowing in or sucking out special pull lines in pipe work that has already been laid.
  • Page 6 A worn fan housing (cracks, nicks, chips) may result in an increased risk of injury from thrown foreign objects • If either the fan wheel or fan housing is damaged, consult your dealer – ZEITLER AG recommends you contact a service dealer •...
  • Page 7 Do not service or store your machine near open flames. Check the fuel filler cap for leaks at regular intervals. Use only a spark plug of the type approved by ZEITLER AG and make sure it is in good condition – see ‘Technical data’.
  • Page 8: Scope Of Supply Ez300

    Blowing pull line into cable conduits (ø 25-200 mm) Scope of supply EZ300 Art. 100086 EZ300 Pull Line Blower, in original plastic carrying case with standard equipment Standard equipment EZ300 includes Art.100087 Blowing connection Art.100088 Suction connection Art.100073 Special equipment for small int. Ø from 25 to 50 mm consisting of special black adapter plus special nozzle Art.100105 Head piece 140 with pull line supply (for int Ø...
  • Page 9 Blowing pull line into cable conduits (ø 25-200 mm) Small case with parachutes Art.100152 Green, for int. conduit Ø of 60 to 100 mm Art.100153 Blue, for int. conduit Ø of 100 to 150 mm Art.100075 Cone orange, with metallic head for int.
  • Page 10: Optional Accessories And Expendable Materials

    Tubulure 40 to foam body for int. Ø of conduits 80 to 100 mm Art.100129 Tubulure 70 to foam body for int. Ø of conduits 120 to 200 mm For details see ADDENDUM DISKS AND AXLES (www.zeitler.swiss) Art.100309 Parachute for conduits int. Ø 30 - 60 mm Art.100154...
  • Page 11: Special Pull Line

    Blowing pull line into cable conduits (ø 25-200 mm) Special Pull line Art.100132 Pull line rolls ø 1 mm, approx. 900 m length, tensile strength approx. 24 kg box of 10 rolls Art.100716 Pull line toneable with copper wire ø 1 mm, approx. 820 m length, tensile strength approx.
  • Page 12: Shuttle Assembling

    Blowing pull line into cable conduits (ø 25-200 mm) Shuttle Assembling Assemble at each end of axle 2 washers 1 disk (black or white) 1 screw with hole Tighten with the two open end wrenches NEVER USE SHUTTLE WITHOUT PULL LINE – COULD GET LOST! Operating Manual EZ300 Version 05/2021 page 12 / 30...
  • Page 13: How To Use Accessories

    Blowing pull line into cable conduits (ø 25-200 mm) How to Use Accessories Head piece 140 and 200 plus special equipment For every application, fix connection and head piece corresponding to the interior conduit Ø. Head piece 140 for Ø 50 to140 mm, Head piece 200 for Ø...
  • Page 14: Blowing Mode With Ez300

    Blowing pull line into cable conduits (ø 25-200 mm) Blowing mode with EZ300 Conduit ends must be clean and cut off evenly (if not possible → use orange cone) Decide on the conduit end at higher level Post control person on opposite side (where device is not in use). (eye protection, wear safety goggles) Fill the tank with the mixture of gasoline and engine oil –...
  • Page 15: Suction Mode With Ez300

    Blowing pull line into cable conduits (ø 25-200 mm) Suction Mode with EZ300 Only change to suction mode if blowing mode does not work (Never use with water in the conduit!) Conduit ends must be clean and cut off evenly Decide on the conduit end at higher level Open the intake screen with the screwdriver Adjust suction connection (bayonet catch)
  • Page 16: Fuel

    For health reasons, avoid direct skin contact with gasoline and avoid inhaling gasoline vapor. STIHL MotoMix ZEITLER AG recommends the use of STIHL MotoMix. This ready-to-use fuel mix contains no benzol or lead, has high octane rating and ensures that you always use the right mix ratio.
  • Page 17: Fueling

    Blowing pull line into cable conduits (ø 25-200 mm) Storing Fuel Store fuel only in approved safety-type fuel canisters in a dry, cool and safe location protected from light and sun. Fuel mix ages – only mix sufficient fuel for a few weeks work. Do not store fuel mix for longer than 3 months. Exposure to light, sun, low or high temperatures can quickly make the fuel mix unusable.
  • Page 18: Starting / Stopping The Engine

    Blowing pull line into cable conduits (ø 25-200 mm) Starting / Stopping the Engine Starting the engine • Observe safety precautions • Press the fuel pump bulb (1) at least five times – even if the bulb is filled with fuel Adjusting the setting lever •...
  • Page 19 Blowing pull line into cable conduits (ø 25-200 mm) Starting • Place the unit on safe ground • Make sure you have a firm footing: Hold the unit firmly with your right hand on the housing and press down • Hold the starter grip with your left hand •...
  • Page 20: Cleaning The Air Filter

    Blowing pull line into cable conduits (ø 25-200 mm) Cleaning the Air Filter If there is a noticeable loss of engine power • Turn the filter cover lock (1) counterclockwise to the vertical position. • Remove the filter cover (2) •...
  • Page 21 Blowing pull line into cable conduits (ø 25-200 mm) Fine Tuning for Operation in Mountains or at Sea Level A slight correction of the setting may be necessary if engine power is not satisfactory when operating at high altitude or at sea level. •...
  • Page 22: Checking The Spark Plug

    Fit a new spark plug after about 100 operating hours – or sooner if the electrodes are badly eroded. Install only suppressed spark plugs of the type approved by ZEITLER AG – see “Specifications”. To reduce the risk of arcing and fire If the spark plug comes with a detachable adapter nut: •...
  • Page 23: Engine Running Behaviour

    • Have the muffler checked for contamination (carbonization) ZEITLER AG recommends that you have servicing and repair work carried out exclusively by an authorized servicing dealer. Rewind Starter To help prolong the wear life of the starter rope, observe the following points: •...
  • Page 24: Maintenance And Care

    Blowing pull line into cable conduits (ø 25-200 mm) Maintenance and Care The following intervals apply to normal operating conditions only. If your daily working time is longer or operating conditions are difficult (very dusty work area, etc), shorten the specified intervals accordingly Visual inspection (condition, leaks) Complete machine Clean...
  • Page 25: Minimize Wear And Avoid Damage

    ZEITLER AG recommends that you have servicing and repair work carried out exclusively by an authorized servicing dealer. Dealers are regularly given the opportunity to attend training courses and are supplied with the necessary technical information.
  • Page 26: Support

    Blowing pull line into cable conduits (ø 25-200 mm) Support First Name: ____________________ Company: ____________________ Last Name: ____________________ Phone: ____________________ e-mail: ____________________ Website: ____________________ Duct outside Ø: Duct length: Duct inside Ø: Does air go through the duct? don’t know Is there water in the duct? Have you tried to blow from opposite? Duct occupied?
  • Page 27: Main Parts Ez300

    Blowing pull line into cable conduits (ø 25-200 mm) Main Parts EZ300 Spark plug boot Setting lever Fuel pump Carburetor Starter grip adjusting screw Filter cover and Filter cover lock Fuel filler cap Fuel tank Muffler Choke knob Handle Throttle trigger Control handle Intake screen...
  • Page 28: Technical Data Ez300

    Blowing pull line into cable conduits (ø 25-200 mm) Technical Data EZ300 Engine Single cylinder two-stroke engine Displacement 27,2 cm³ Bore 34 mm Stroke 30 mm Idle speed 2500 1/min Engine power to ISO 7293 0,8 kW (1,1 PS) Ignition System Electronic magneto ignition Spark plug (suppressed) NGK CMR 6 H...
  • Page 29: Maintenance And Repairs

    All other repairs must be carried out by an authorized servicing dealer. Only use genuine replacement parts and accessories that are explicitly approved for the EZ300 by ZEITLER AG. These parts are specifically designed to match your machine model and meet your performance requirements and also to avoid the risk of accidents and damage to the machine.
  • Page 30: Ec Declaration Of Conformity

    Blowing pull line into cable conduits (ø 25-200 mm) EC Declaration of Conformity ZEITLER AG Sonnhalde 7 CH-6206 Neuenkirch SWITZERLAND Certify that the new machine described below Category Tool to blow in or suck out special pull line in conduits...