BLKG interval Tb = 15 + n (n stands for the partial scanning setting value. When the 10th digit is 2 and the first digit is 6, n=26. The maximum value of
n is 99, and the minimum value of Tb is 45. When Tb≤45, the BLKG interval is 45H, the constant value.
Effective lines X = Tv – Tb
External VD interval
Tv [line]
312.5 (10.0 ms)
156 (5.00 ms)
104 (3.32 ms)
78 (2.50 ms)
BLKG interval Tb = 15 + n (n stands for the partial scanning setting value. When the 10th digit is 1 and the first digit is 3, n=13. The maximum value of
n is 49, and the minimum value of Tb is 25. When Tb≤25, the BLKG interval is 25H, the constant value.
Effective lines X = Tv – Tb
* The number of effective lines in the 2I mode indicates the number of lines output from the Video 1 and 2 connectors.
– Determine and input each value for the colored columns.