Specifications Of The External Hd And Vd Outputs; Specifications Of The Wen Output; Specifications Of The Trigger Pulse - Sony XC-HR300 Technical Manual

Ccd black-and-white video camera module
Table of Contents

Advertisement

Specifications of the External
HD/VD Outputs
HD
VD
The amplitude level is the typical value when
terminated with 10 kΩ. The external HD and VD can
be output when you set the INT/EXT switch to INT.
Specifications of the WEN
Output
625 H(1N)
312.5 H(2I)
The amplitude level is the typical value when
terminated with 10 kΩ. When the partial scanning is
used, the pulse width is less than the above value.
Specifications of the Trigger
Pulse
4.5V
0V
4.5V
0V
• Input impedance; 10 kΩ or more.
• The voltage and pulse width used are measured at pin
11 of a 12-pin multi-connector on the rear panel.
4.5V
0V
2 µ sec to 1/4 sec
Mode Setting
4 to 5.0V
0 to 1.0V
9