S S t t e e p p 4 4 — — U U n n i i t t I I n n s s t t a a l l l l a a t t i i o o n n
I I m m p p o o r r t t a a n n t t : : Do not lift the unit without test lifting for
balance and rigging. Do not lift the unit in
windy conditions or above personnel. Do
not lift the unit by attaching clevis, hooks,
pins, or bolts to the unit casing, casing
hardware, corner lugs, angles, tabs, or
flanges. Failure to observe these warnings
may result in equipment damage.
1. Before preparing the unit for lifting, check the unit
dimension drawings for center of gravity for lifting
safety (Figures
"Step 2 — Determine Unit
Clearances," p.
5). Because of placement of internal
components, the unit's weight may be unevenly
distributed. Approximate unit weights are also
provided in the unit drawings.
N N o o t t e e : : Unit rigging and hoisting requires accessory kit
BAYLIFT002A. It includes a kit of four (4) lifting
lugs.
2. Insert the four lifting lugs in the openings provided
in the drip lip on each end of the unit. A tap or jerk
to the lug will overcome the interference that arises
due to the dimple on the lug.
3. When hoisting the unit, be sure that a proper
method of rigging is used. Use slings and spreader
bars for protection during lifting. Always test-lift the
unit to determine the exact unit balance and
stability before hoisting it to the installation
location.
4. When the curb and air ducts have been properly
installed, the unit is ready to be hoisted to the roof
and set in position.
I I m m p p o o r r t t a a n n t t : :
To prevent damage to the sides and top
of the unit when hoisting use "spreader
bars".
The unit must be lowered into position.
The P.V.C. rubber tape on the curb
flange permits the unit to be
repositioned if required without
destroying the P.V.C. rubber seals
affixed to the mounting curb.
P P l l a a c c i i n n g g t t h h e e U U n n i i t t o o n n t t h h e e M M o o u u n n t t i i n n g g C C u u r r b b
1. The unit is designed with a perimeter drip lip that is
lower than the unit base pan.
2. Position the unit drip lip down over and in contact
with the outside corner of the curb. Continue to
lower the unit on top of the curb, with the unit drip
lip astraddle, and in contact with, both the end and
side rail of the curb. The unit should now rest on
top of the curb. Use the extreme mounting kit,
BAYEXMK001A, to add additional hold down
strength to the mounting.
10
R R o o o o f f t t o o p p I I n n s s t t a a l l l l a a t t i i o o n n — — F F r r a a m m e e M M o o u u n n t t i i n n g g
For rooftop applications using field fabricated frame
and ducts use the following procedure:
1. Prepare the hole in the roof in advance of installing
the unit.
2. Secure the horizontal or down airflow ducts to the
roof. Refer to the previous Convert from Horizontal
Airflow to Down Airflow section if conversion is
needed.
3. All fabricated outdoor ducts should be as short as
possible.
4. Place the unit on the frame.
5. The unit must be mounted level for proper drainage
of water through the holes in the base pan.
6. Secure the unit to the frame.
7. Insulate any ductwork outside of the structure with
at least two (2) inches of insulation and then
weatherproof. There must be a weatherproof seal
where the duct enters the structure.
8. The unit should not be exposed to direct roof water
runoff.
9. Flexible duct connectors must be of a flame
retardant material. All duct work outside of the
structure must be insulated and weatherproofed in
accordance with local codes.
10. Access and service clearances for the unit must be
given careful consideration when locating the duct
entrance openings. Figures
Unit Clearances," p. 5
11. Continue with the following installation sections to
complete the installation: Ductwork, Filter, and
Electrical Wiring.
R R o o o o f f t t o o p p I I n n s s t t a a l l l l a a t t i i o o n n — — F F r r a a m m e e M M o o u u n n t t i i n n g g
For roof top applications using field fabricated ducts
and sleeper rails rather than a curb or frame, use the
following procedure:
1. Locate and secure the sleeper rails to the roof by
bolting (three (3) rails required). One on each end to
support the edges of the unit and one across the
center of the unit. The center rail must run inside
both drip lips. Vibration isolators should be
installed, adjust as necessary for your sleeper rails.
The isolators must be placed on base pan, not drip
lip. Add flashing as required. Flashing must
conform to local building codes.
2. Prepare the hole in the roof in advance of installing
the unit.
3. Secure the horizontal or down airflow ducts to the
roof. Refer to the previous Convert from Horizontal
Airflow to Down Airflow section if conversion is
needed.
4. All fabricated outdoor ducts should be as short as
possible.
5. Place the unit on the rails.
6. The unit must be mounted level for proper drainage
of water through the holes in the base pan.
"Step 2 — Determine
provide unit dimensions.
88-4YCA4001-1A-EN