Kowa KGC-01 Instruction Manual

Lubricating systems grease checker

Advertisement

Quick Links

K O WA L U B R I C AT I N G S Y S T E M S
GREASE CHECKER
MODEL : KGC-01 / KGC-02
INSTRUCTION MANUAL
KOWA CORPORATION
Writing:May , 2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KGC-01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kowa KGC-01

  • Page 1 K O WA L U B R I C AT I N G S Y S T E M S GREASE CHECKER MODEL : KGC-01 / KGC-02 INSTRUCTION MANUAL KOWA CORPORATION Writing:May , 2020...
  • Page 2 Introduction Thank you very much for purchasing the KOWA LUBRICATING SYSTEM. This Instruction Manual has been compiled as a practical guide for the operation and maintenance of the Grease Checker. All descriptions contained herein are based on the standard system, which may, therefore, be different from those of the purchased system.
  • Page 3 PRECAUTIONS OF SAFETY Before the installation, operation, maintenance and inspection, read carefully this ○ instruction manual and other accompanying documents for correct service. Familiarize with the knowledge of equipment, information of safety and all of cautionary instructions for service. The precautions of safety are shown in each equipment of the centralized lubricating system by using safety mark.
  • Page 4 Precautions for use 1. Precautions for mounting and piping A. When installing, make sure no foreign matter such as dust gets into the equipment and piping. It may cause malfunction or failure. In addition, do not drop it, as dropping it may distort or damage internal parts and cause malfunction.
  • Page 5: Table Of Contents

    Table of Contents 1. Overview ···································································· 2 2. Composition ································································ 2 3. Specification ······························································· 2 4. Usage ········································································ 3 5. Maintenance and inspection ·········································· 4 6. Operating method and precautions for use ······················ 4 7. Precautions for installation ··········································· 5 8.
  • Page 6: Overview

    When grease is sent to the grease checker, the attached indicator will perform a stroke operation and you can confirm that the grease has been sent. 3. Specification Model KGC-01 KGC-02 Operating Oil Content About 0.5 ㎤ About 0.2-0.3MPa...
  • Page 7: Usage

    (Figure. 4) ※When using a manual or electric grease gun, pay attention to the discharge pressure and do not exceed the grease checker operating pressure of Max.3MPa. ※ Figures are KGC-01 Figure. 1 Figure. 2 Figure.
  • Page 8: Maintenance And Inspection

    5. Maintenance and inspection No special maintenance or inspection is required, but be careful not to let dust in the grease. Also, check and clean it so that dust and sand do not adhere to the indicator mounted to the grease checker and the grease nipple.
  • Page 9: Precautions For Installation

    7. Notes on installation The grease checker has a structure in which the indicator is manually pushed back after it operates. Install the grease checker within the reach of people. Do not install the grease checker with the indicator attached to the grease checker facing downward.
  • Page 10: Troubleshooting

    8. Troubleshooting Conditions Possible Causes How to deal with Reset again after a while Push down the indicator all the way to release the grease inside. High back pressure and Indicator pushed back on Turn adjusting high pressure loss reset counterclockwise as seen from the behind grease checker discharge side to reduce the cracking...

This manual is also suitable for:

Kgc-02

Table of Contents