K4
K4 ON/OFF CONTROL
FOR USE WITH AMEREC
AK STEAM GENERATORS
FOR THE SAFETY OF YOU AND YOUR FAMILY PLEASE READ THE
WARNINGS TO THE RIGHT AND ALL INSTRUCTIONS BEFORE USING
YOUR STEAMBATH.
POST SAFETY "WARNINGS" LABEL OUTSIDE STEAMBATH THIS IS
A REQUIRED POSTING ON DOOR OF STEAM ROOM OR ADJACENT
TO DOOR FOR ALL COMMERCIAL INSTALLATIONS.
Thank you for purchasing your new AMEREC steam generator. If we can be of any assis-
tance do not hesitate to call our Service Department at 1-800-363-0251 or 1-320-286-3500.
SECTION 1: OPERATION OF YOUR K4 AND AMEREC GENERATOR
The K4 control does not provide automatic temperature control. Use the on/off button to
control the temperature as desired by turning the steam bath on and off as needed.
Note: the K4 may be used as an extra switch when a temperature regulating K2, K3
and/or KT3 control is installed. Contact Technical support for further information.
1. Ensure that both the power circuit and water supply to the generator are ON.
2. To activate the steam, press the K4 control's On/Off switch. In 10 to 20 minutes the
room should be comfortable enough to begin taking a steam bath. The unit will turn off
automatically in 30 minutes.
3. Remove clothing and jewelry.
4. Enter the steam room and close the door to prevent steam from escaping.
5. Relax and enjoy the warm steam releasing tense muscles and refreshing the entire
body. The average time spent taking a steam bath is approximately 10 minutes
6. Pressing the control while the steam generator is operating will shut it off.
7. If your steam room has a shower, a pleasant experience can be achieved by taking
a warm shower while in the steam. You will find the contrast from water to steam quite
invigorating.
4209-45
08/06/21
Technical Support: 1-320-286-3500
K4 On/Off Control Owners Manual
SAVE THIS MANUAL
AK STEAM GENERATOR
1-800-363-0251
WARNING
Electrical grounding is required
on all Steam Generators.
All electrical supplies should be
disconnected when servicing a
Steam Generator.
All wiring must be installed by a
licensed electrical contractor in
accordance with local and
national codes.
All plumbing must be installed
by a licensed plumber in
accordance with all applicable
local and national codes.
Steamers are for indoor use only.
Steamers are not for
space-heating purposes.
Be certain that steam bath
enclosures are properly sealed
to avoid water damage from
escaping steam. It is
recommended that 100%
silicone caulk be used to seal
all pipes and fittings. Steam
must be prevented from
escaping into the wall cavity.
Never shut off the water to an
appliance that is in use.
Electric Shock Hazard
High Voltage exists within this
equipment.
There are no user serviceable parts
in this equipment.
WA RNING
REDUCE THE RISK OF
OVERHEA TING AND SCALDING
1. Exit immediately if uncom fortable, dizzy or slee py. St aying too long in
a heated area is capa
ble of causing overheating.
2. Supe rvise children at all tim es .
3. Chec k with a doctor be fore use if pregnant, diabetic , in poor health or
under medical car e.
4. Breathing heated air in conjunction with consumption of alcohol, dr
or medication is capa ble of causing unconsciousnes s.
CA UTION!
Do not contact steam head . St ay at least 12" away
from hot steam escaping from the steam outlet.
REDUCE THE RISK OF
SLIPPING AND F
ALL INJU RY
Use care when enter ing or exiting the steam room, floor ma y be slippe ry.
05-21-07
NO TE : Fo r additional sa fety instr uctions, see owner's manual .
4110-79
support@amerec.com
ugs
Need help?
Do you have a question about the K4 and is the answer not in the manual?
Questions and answers