FMUser FUTV4502D User Manual

Dvb-s3 modulator

Advertisement

Quick Links

FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司
FUTV4502D
DVB-S2 Modulator
User's Manual
NMS Version: 5.5.16
SW: 1.22
HW: 4.0
FMUSER International Group Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FUTV4502D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FMUser FUTV4502D

  • Page 1 FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 FUTV4502D DVB-S2 Modulator User’s Manual NMS Version: 5.5.16 SW: 1.22 HW: 4.0 FMUSER International Group Inc.
  • Page 2: Table Of Contents

    3.2 GENERAL SETTING ............20 CHAPTER 4 NMS SETTING ..............20 4.1 INSTALLATION ............20 4.2 SOFTWARE OPERATION ....... 24 4.3 FUTV4502D DVB-S2 MODULATOR OPERATION ..............30 4.4 OTHER SETTINGS ............ 33 CHAPTER 5 TROUBLESHOOTING ............34 CHAPTER 6 PACKING LIST...
  • Page 3: Chapter 1 Product Outline

    Chapter 1 Product Outline 1.1 Outline The FMUSER FUTV4502D DVB-S2 modulator (with BISS) is a high performance modulator developed according to DVB-S2 (EN302307) standard which is the standard of second generation of the European broadband satellite telecommunication. It supports ASI or IP signal input and QPSK-S2 output.
  • Page 4: Specifications

    广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 1.4 Specifications Supporting Both Packet And Byte Mode TS Input 4 ASI Inputs, Supporting Hot Backup ASI Input Supporting 188/204Byte Transmission Stream Packet ASI Input Connector: BNC, Impedance 75 IP Input 1XIP Input (Rj45, 100M TS Over UDP)
  • Page 5: Appearance And Description

    广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 1.5 Appearance and Description Front Panel Illustration Indicator area: All the indicators will light on when DVB –S2 modulator works at current mode. 3 / 36...
  • Page 6 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. Rear Panel Illustration RF Output Interface ASI1Input channel 1-4 Data Port Network Management System Interface Input of 10Mhz Reference Clock Loop out of 10Mhz Internal Clock Power Switch Fuse Power Socket Grounding pole 4 / 36...
  • Page 7: Chapter 2 Installation Guide

    2.1 Acquisition Check When user opens the package of the device, it is necessary to check items according to packing list. Normally it should include the following items: l FUTV4502D DVB-S2 Modulator l User’s Manual l ASI Cable l Power Cord If any item is missing or mismatching with the list above, please contact local dealer.
  • Page 8 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 2.2.2 Environment Requirement Item Requirement When user installs machine frame array in one machine hall, the Machine Hall Space distance between 2 rows of machine frames should be 1.2~1.5m and the distance against wall should be no less than 0.8m.
  • Page 9: Wire's Connection

    When the device adopts united way, the grounding resistance should be smaller than 1 . FCaution: Before connecting power cord to FUTV4502D DVB-S2 modulator, user should set the power switch to “OFF”. 7 / 36...
  • Page 10: Signal Cable Connection

    广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 2.4 Signal Cable Connection The signal connections include the connection of input signal cable and the connection of output signal cable. The details are as follows: 2.4.1 ASI input and loop output cable illustration: 2.4.2 RF output interface connection User can firstly find the RF out interface on the device according to the connector mark described on the rear panel illustration, and then connect the coaxial cable (in the accessories).
  • Page 11: Chapter 3 Operation

    FMUSER INTERNATIONAL GROUP INC. Chapter 3 Operation FUTV4502D DVB-S2 modulator’s front panel is user operation interface. Before operating, user can decide whether directly use the default setting or customize the input and output parameters setting. The detail operations go as follows: Keyboard Function Description: LEFT/RIGHT: To choose and set the parameters.
  • Page 12: General Setting

    广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 3.2 General setting By pressing “LOCK” key to enter the main menu, the LCD will display the following pages: 1 Alarm Status 2 System Setting 3 Output Setting 4 Network Setting 5 Saving Config 6 Loading Config...
  • Page 13 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. Current TS Rate: 38.01 Mbps Alarm Count: 4 1. Clock Lose 2. No input TS 3. Input TS Overflow 4. Internal Error 3.2.2 System setting By pressing UP/DOWN or LEFT/RIGHT to choose this item, ENTER and LEFT/RIGHT to set the parameters.
  • Page 14 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 3.2.2.2 Reference Clock Select After entering the submenu by pressing ENTER key, user can choose from which the “Reference Clock” comes. 2.2 REF Clock Sel internal 2.2 REF Clock Sel internal ] external auto Internal: This modulator uses internal 10MHz crystal oscillator as reference clock.
  • Page 15 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 3.2.2.5 Symbol rate 2.5 Symbol Rate Max Input = 38.01 Mbps 27.500M Adjustable Range: DVB-S: 0.5-45M; DVB-S2: 0.5-30M 3.2.2.6 Roll-off Factor 2.6 Roll Off 0 .35 2.6 Roll Off [ 0.35 ] 0.25 0 .20 User can set the roll-off factor of the DVB-S and DVB-S2 There are 3 possible options, including 0.35, 0.25 and 0.20.
  • Page 16 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. User can set FEC value at this submenu when modulator works as DVB-S2 modulator. The possible FEC rates include 1/4, 1/3, 2/5, 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10 when the constellation is QPSK.
  • Page 17 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 3.2.2.10 BISS Setting There are three Biss modes to select: Mode 0, Mode 1, Mode E. 2.10.1 Biss Mode [ Mode 0] Mode 1 Mode E When the modulator works under Mode 1, user can select and scramble the input programs manually by entering submenu 2.10.2 and set SW data (Users can input 12 characters from 0, 1, 2, 3,...
  • Page 18 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 3.2.3 Output Setting Pressing UP/DOWN or LEFT/RIGHT to choose this item, ENTER and LEFT/RIGHT to set the parameters. The system displays following page: 3.1 RF Frequency 3.2 RF Level ATT 3.3 Spec Invert 3.4 RF Output 3.5 RF 10M Enable...
  • Page 19 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 3.2.3.4 RF Output 3.4 RF Output single tone 3.4 RF Output [ single tone ] modulation User can set the RF output mode for different applications. Single Tone: the RF output is only carrier without modulation.
  • Page 20 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. Off: Turn off the RF output. 3.2.3.4 RF 10M Enable Under this menu, users can decide turn on or off the 10MHz reference clock. 3.5 RF 10M Enable 3.2.4 Network setting Press “Up/Down” to choose this item. “Enter” and “Left/Right” to set the parameters. The system displays following pages.
  • Page 21 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 4.1 IP Address 192.168.000.136 4.2 Subnet Mask 255.255.255.000 4.3 Gateway 192.168.000.001 4.4 Console Address 192.168.000.221 4.5 MAC Address 201205041016 3.2.5 Saving Configuration User can choose to save the current configured parameters by pressing ENTER key. The system...
  • Page 22: Chapter 4 Nms Setting

    广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. Chapter 4 NMS Setting Network Management System Profile Network management system is applied to digital TV equipment operation, control and management and parameters setting, etc. It centralizes digital TV equipment through network. 4.1 Installation The software doesn’t need special installation. User can just copy “Network Management Software X.XXY.exe”...
  • Page 23 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 4.2.2 Main Interface User can create a device node tree in the left column by adding, modifying and deleting the device node. This software provides a powerful node operation function, and the user can edit various parameters in the device tree for management and classification.
  • Page 24 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. The Add Freq Point dialog box popes up when the user clicks the Add Freq Point item in the Edit pull down menu on the menu row. The device will confirm the given frequency while user clicks User can also click right mouse key to pop up the short-cut menu in device tree or in the left blank column, then the corresponding dialog box will pop up by choosing Add Main Freq Point.
  • Page 25 “ ” or click “?” to auto search. NOTE: The default IP address of FUTV4502D DVB-S2 modulator is 192.168.0.136, also you can check its IP address in the front panel of device in case the IP changed unexpected. 2. The PC IP address and device IP address should be in the same network. For example the Device IP is 192.168.0.136, sub mask is 255.255.255.0.
  • Page 26: Futv4502D Dvb-S2 Modulator Operation

    4.3 FUTV4502D DVB-S2 Modulator Operation User can choose the DVB-S2 modulator in the device tree. 24 / 36...
  • Page 27 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. Set: making the current parameters, which show in the NMS software, activate. Get: reading the current device’s activating parameters and show them on NMS software. 4.3.1 General Parameters Setting Ø Modulation Mode User can select the modulator’s working mode and relevant constellation at this drop-down list.
  • Page 28 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. Internal: This modulator uses internal 10MHz crystal oscillator as reference clock. External: This modulator uses external 10 MHz input as reference clock. Auto: The modulator will preferably select the external 10MHz input if it exists. Otherwise the modulator will select the internal 10MHz crystal oscillator’s output as reference clock.
  • Page 29 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. modulator. The possible FEC rates include 1/4, 1/3, 2/5, 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10 when the constellation is QPSK, and 3/5, 2/3, 3/4, 5/6, 8/9, 9/10 when the constellation is 8PSK. Ø Pilot Insert : User can choose whether to insert the Pilot in the check box.
  • Page 30 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. Ø 10M Reference Clock : User can decide whether to apply the 10M reference clock by checking this checkbox. 4.3.2 BISS Data Setting There are 3 scramble modes: Mode 0, Mode 1, and Mode E.
  • Page 31 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. Users can select Mode 1 in the drop-down menu, and then input the scrambler key. The scrambler key consists of 12 characters from 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, and F. The downside device descrambler key equals SW Data on the BISS scrambler side.
  • Page 32: Other Settings

    广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. Users can scramble the input programs in this interface. : Input programs parsing : The parsing overtime value : To refresh the inputting terminal and get the inputting information : To refresh the outputting terminal and get the outputting information : To move the input program from left box to the right box to complete scrambling.
  • Page 33 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. Users can note the indicator light turns red (see below), which signifies the equipment has disconnected. Users then can refer to below prompts to edit the property by inputting the new IP to re-connect the equipment.
  • Page 34 广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. 4.4.3 User Add When logging in, user will note that the default user name is admin and no password. User can add users and passwords as needed. User clicking “Setting” in the menu bar and selecting “User Setting” in the pull-down list, the below dialog box will pop out as shown below.
  • Page 35: Chapter 5 Troubleshooting

    FMUSER’s ISO9001 quality assurance system has been approved by CQC organization. For guarantee the products’ quality, reliability and stability. All FMUSER products have been passed the testing and inspection before ship out factory. The testing and inspection scheme already covers all the Optical, Electronic and Mechanical criteria which have been published by FMUSER.
  • Page 36: Chapter 6 Packing List

    广州市汉婷生物技术开发有限公司 FMUSER INTERNATIONAL GROUP INC. Chapter 6 Packing List l FUTV4502D DVB-S2 modulator 1pcs l User’s manual 1pcs l Power cord 1pcs l ASI wire 4pcs 34 / 36...

Table of Contents