Page 1
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 FUTV4443 4 in 1 Mux-Scrambling QAM Modulator User’s Manual NMS Version: NMS 5.0.20 SW: 0.22 HW: 1.0 FMUSER International Group Inc...
Chapter 1 Product Outline 1.1 Outline FUTV4443 is a cost effective integrated 4 in 1 QAM modulator supporting multiplexing and scrambling. This device supports maximum 16 ASI input, after 4 multiplexer and 4 scrambler process, then gives 4 carriers output (4 adjacent frequency output by 1 RF port).
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 1.4 Specifications Input 16 x ASI inputs, BNC interface input 16 x ASI Output Channel Max PIDs 256 per channel Multiplexer PID remapping(auto/manually optional) Functions PCR accurate adjusting PSI/SI table automatically generating simu-encrypt Scrambling Scramble Standard...
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Chapter 2 Appearance and Illustration Indicator area: All the indicators will light on when the 4 in 1 Mux-Scrambling QAM works at current state. 2.1 Front Panel: 2.2 Rear Panel: ASI 1-16 IN Channel 1-16 ASI Input...
Page 6
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Power Power Socket Grounding Grounding Pole 4 / 42...
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Chapter 3 Installation Guide 3.1 Acquisition check When users open the package of the device, it is necessary to check items according to packing list. Normally it should include the f ollowing items: l 4 IN 1 Mux-Scrambling QAM l User’s Manual...
Page 8
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 3.2.2 Environment Requirement Item Requirement W hen us er install mac hine frame array in one mac hine hall, the distanc e between 2 Machine hall spac e machine frames should 1.2~1.5m and the distanc e to wall should be no less than 0.8m。...
Page 9
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 lightning arresting and interference rejection. Therefore, system must follow this rule: 1. Coaxial cable’s outer conductor and isolation layer should keep sound electric conducting with the metal housing of device. 2. Grounding conductor must adopt copper conductor in order to reduc e high frequency impedance, and the grounding wire must be as thick and short as possible.
Page 10
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 the device adopts united way, the grounding resistance should be less than 1 FCaution: Before connecting power cord to 4 in 1 Mux-Scrambling QAM, user should set the power switch to “OFF”. 3.2.4.1 Signal wire connection of ASI IN...
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Chapter 4 Operation 4.1 Operation FUTV4443 4 in 1 Mux-Scrambling QAM’s front panel is user operation interface. Before operating, user can decide whether directly use the default setting or customize the input and output parameters. The detail...
Page 12
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 4.2.1 General Setting By pressing “LOCK” key to enter the main menu, the LCD will display the main menu as the f ollowing pages: 1 System Setting Input Setting 3 Output Setting Network Setting 5 Saving Config...
Page 13
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 frequency by moving the UP/DOW N/LEFT/RIGHT key and then repress ENTER to save. 1.1.1 Frequency 586.00 MHz 1.1.1 Frequency 586.00 MHz The RF output range is from 48MHz~1000MHz with 6/8M bandwidth. More details will be illustrated in the NMS operation.
Page 14
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 at the same symbol rate. Accordingly, with the TS coding rate increasing, the signals’ anti-jamming capability will become weaker. Hence, those wired network currently in effect usually adopt QAM modulation mode no exceeding 64QAM. What needs to be pointed out is, the effective coding rate this modulator can transport is limitary when the device works as different constellations and symbol rates.
Page 15
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 The symbol rate range is from 5.0~7.0 Msps in 1ksps step. Note: W hen users choose 6M as the frequency point bandwidth, the symbol rate should not exceed 5.217Msps; When users choose 8M as the frequency point bandwidth, the symbol rate should not exceed 6.956Msps.
Page 16
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 ENTER to confirm. 1.6 RF Level +00.0 1.6 RF Level +00.0 The total level attenuation range is from 6~-25db in 0.5db step. 4.2.3 Input Setting User can select “Input setting” in the main interface and then press ENETR to view the inputting ports.
Page 17
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 display shows as below: 3.1.1 Output Carrier 3.1.2 Attenuation 3.1.3 NIT Insertion 4.2.4.1 Output carrier User can decide whether to turn on the carrier of output 1’ or not. By pressing ENTER after selecting the “Output Carrier”, moving the LEFT/RIGHT key to set, repressing ENTER to confirm.
Page 18
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 3.1.3 NIT Insertion *Off 3.1.3 NIT Insertion ?Off Note: User can decide whether to make the inserted NIT table effective. The operation of output 2, output 3 and output 4 is the same as output 1.
Page 19
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 4.5.1 SCR IP Address 1 4.5.2 SCR IP Address 2 4.5.3 SCR IP Address 3 4.5.4 SCR IP Address 4 4.5.1 SCR IP Address 1 192.168.002.002 4.2.6 Saving configuration User can choose to save the current configured parameters by pressing ENTER key.
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Chapter 5 NMS Setting Network Management System Profile Network management system is applied to digital TV equipment operation, control, management and parameters setting, etc. It centralizes digital TV equipment through network. 5.1 Installation The software doesn’t need special installation. User can just copy “Network Management Software X.XXY.exe”...
Page 21
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 and password. Upon the inputs, the software will verify them with database record automatically. If both of them are correct, the main interface will appear. Both of the default user name and password are admin.
Page 22
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.2.4 Adding Equipment under Given Frequency Point User should choose the frequency point in advance, and then the dialog box of Add Equipment will pop up when user clicks Add Equipment item in the Edit...
Page 23
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.2.5 Edit Equipment Interface User should follow the steps as below: l Inputting the device IP Address l Inputting the device Port Number l Inputting the Equipment Name l Choosing the connected equipment type in drop down list of “Equipment Type”...
Page 24
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 NOTE: The default IP of FUTV4812A is 192.168.2.1, also you can check its IP address in the front panel of device in case the IP changed unexpected. The NMS PC IP address and device IP address should be in the same network.
5.3 FUTV4443 4 in 1 Mux-Scrambling QAM Operation User can choose the “FUTV4443 testing” in the device tree. Set: making the current parameters, which show in the NMS software, 23 / 42...
Page 26
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 activate. Get: reading the current device’s activating parameters and show them on NMS software. 5.3.1 Mux/Scrambler Setting In this field, users can set and get the device inputting parameters 5.3.1.1 Mux 5.3.1.1.1 In this box, all 16 inputting ports are displayed in the left box. User can select any port and scan all the programs contained in each port by clicking PARSE button at the bottom left corner.
Page 27
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.3.1.1.2 Programs refresh input/out User can select the program to be multiplexd and click the arrow add it to the right box, or user can delete the programs which have been multiplexed from the right box by clicking the arrow...
Page 28
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.3.1.1.3 Program Modification 26 / 42...
Page 29
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 In case the user intend to customize the details of the programs, user can select the target program and click Modify Prg button between the 2 boxes, then the modify interface pops out as shown above. User can select the item to be modified and input new information in the corresponding box below.
Page 30
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.3.1.2 Scrambler Setting 28 / 42...
Page 31
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.3.1.2.1 General Introduction ○ This field indicates the current outputting programs and their bit rates. The programs selected will indicate to scramble the corresponding programs. ○ CA channel selecting ○ The indicators of ECMG and EMMG working state, green means it works normally, while red means communication error or no communication.
Page 32
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.3.1.2.3 Crypto Period This field means the scrambling crypto period of the current outputting channels. After the specified crypto period, the CW will be changed to a new one. 5.3.1.2.4 Output Bit-rate This filed means the TOTAL bit-rate of the current output.
Page 33
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 After the modification, users can click the Confirm button to submit the current configuration, and click the Cancel to quit the current operation. 5.3.1.3 Transparent Transport Pass User can decide to bypass the inputting PID as needed in this interface. This interface can be used pass through the EPG table, STB update data, etc.
Page 34
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 By clicking Add button , the below interface will pop out: In this interface, user can input and check the source of PIDs in the first box, the value of PIDs source in the second box and value of outputting PIDs which has been bypassed.
Page 35
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.3.1.4 Parameters User can set the output parameters in this interface, the display shows as below. TS ID: the output 1 TS ID number. SDT: SDT table output or not. Original Network ID: Set the original network ID number.
Page 36
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 934912 5.3.1.5 NIT NIT: Network Information Table. NIT table is a very important table for describing the network and TS. Users can set the parameters of the output NIT table on condition that the NIT Insertion in the interface of Parameter is set Enable.
Page 37
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.3.1.5.1 NIT parameters :The parameter describes the output TS’s network ID :The parameter describes the output TS’s network name 5.3.1.5.2 Insertion private description :This checkbox will allow user to insert the private descriptor into the output TS. The private descriptor includes two parts. One is descriptor tag, and the other is descriptor information.
Page 38
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.3.1.5.3 Replace NIT Table After checking the checkbox, the NIT editing menu is active. And also the device will insert the EIT table into the output TS. :It means to replace the NIT table when users select it, and then users can edit the NIT table and output it.
Page 39
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Modulation standard EN300 429/ITU-T J.83A/B/C Constellation: 16QAM/32QAM/64QAM/128QAM/256QAM optional Symbol Rate range: 5.0~7.0Msps, 1ksp step Bandwidth:6M/8M optional Start Freq: The RF output frequency range is from 48MHz to 1000MHz. Here the start frequency means the centre frequency of TS output.
Page 40
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 NOTE: After completion of configration of all the parameters, click Remote Save button on the toolbar to save the modifications to the device’s flash. 38 / 42...
FMUSER’s ISO9001 quality assurance system has been approved by CQC organization. For guarantee the products’ quality, reliability and stability. All FMUSER products have been passed the testing and inspection before ship out factory. The testing and inspection scheme already covers all the Optical, Electronic and Mechanical criteria which have been published by FMUSER.
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Chapter 7 Packing List l FUTV4443 4in1 Mux-Scrambling QAM l User’s manual l AC Power cord l Grounding wire l ASI wire 16pcs 40 / 42...
Need help?
Do you have a question about the FUTV4443 and is the answer not in the manual?
Questions and answers