FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Chapter 1 Product Outline 1.1 Outline FUTV4443A is a cost effective integrated 4 in 1 QAM modulator supporting multiplexing and scrambling. This device supports maximum 6 DVB-S2 tuner+4 ASI input, after 4 multiplexer and 4 scrambler processes, then gives 4 carriers output (4 adjacent frequency by 1 RF port) and gigabit IP output.
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 1.4 Principle chart Chapter 2 Appearance and Illustration Indicator area: All the indicators will light on when the 4 in 1 Mux-Scrambling QAM works at current state. 2.1 Front Panel: LCD Display POWER:Power Indicator Indicator Alarm:Alarming Indicator...
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 2.2 Rear Panel: Tuner 1-6 IN Channel 1-6 Tuner Input ASI 1-4 IN Channel 1-4 ASI Input Data IP Port NMS Interface RF TEST RF Test Interface RF OUT RF Out Interface Power Power Socket Chapter 3 Installation Guide 3.1 Acquisition check...
Page 7
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 The main content of this chapter including: 1 Checking the possible device missing or damage during the transportation 2 Preparing relevant environment for installation 3 Installing 4 in 1 Mux-Scrambling QAM 4 Connecting signal wires 5 Connecting communication port (if it is necessary) 3.2.1 Device’s installation flow chat illustrated as following...
Page 8
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Requiring device power, air-conditioning power and lighting power are independent to Power each other. Device power requires AC power 100V-240V 50/60Hz 2A Plea se carefully check before running. 3.2.3 Grounding Requirement All function modules’ good grounding designs are the base of reliability and stability of device.
Page 9
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 1. Connecting power cord 2. User can insert one end into power supply outlet, while insert the other end to AC power. 3. Connecting grounding wire 4. When the device solely connects to protective ground, it should adopt independent way, say, sharing the same ground with other devices.
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 l RF Output Cable Illustration: Chapter 4 Operation FUTV4443A 4 in 1 Mux-Scrambling QAM’s front panel is user operation interface. Before operating, user can decide whether directly use the default setting or customize the input and output parameters. The detail operations go as...
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 4.1 LCD Menu Tree 11 / 39...
Page 12
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Prog Parse Sat Freq Set LNB Freq Set 2.1 Port 1 Symbol Rate LNB Voltage 2 Input Setting 1.6 22 KHz Switch (Same content with Port 1 ) 2.8 Port 6 2.8 Port 7 Prog Parse 2.10 Port 7...
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 4.2 Main Interface After switching on the Mux-Scrambling QAM, the LCD will display the starting interface as following page: Data in the first row is the outputting frequency and inputting real-time bit rate of channel 1 and channe2, while data in the second row is of channel 3 and channel 4.2.1 General Setting...
Page 14
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Bandwidth 1.6 RF Level 4.2.2.1 Frequency The RF output range is from 48MHz~1000MHz. 1.1.1 Frequency 586.00 MHz 4.2.2.2 Modulate Mode By pressing “1.2 Modulate Mode”, user can choose the standard of QAM modulation as shown below: 1.2.
Page 15
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 coding rate this modulator can transport is limitary when the device works as different constellations and symbol rates. User can refer to the formula as below: Max_input_bitrate = Symb_rate*qam_bits*188/204 Max input bit rate: the maximum effective inputting coding rate...
Page 16
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 by moving the LEFT/RIGHT key and then repressing ENTER to confirm. 1.5 Bandwidth J.83A/DVB-C *8MHz 7MHz 6MHz J.83A (DVB-C) contains 8MHz, 7MHz, 6MHz; J.83B contains 6MHz; J.83C contains 6MHz; 4.3.2.6 RF Level Setting After entering the submenu by pressing ENTER key, user can set the RF Level by moving the UP/DOWN/LEFT/RIGHT key and then repressing ENTER to confirm.
Page 17
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 The current Port total program number 2.1.1 Prog Parse Port 1 Prog 7 Choose Carrier to outpu Prog 1 CCTV1 The current Port NOTE: 1) When user enters this submenu, user can choose the output program(s) by moving the UP/DOWN key.
Page 18
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Hereby we just take Output 1 as an example to illustrate. User can choose output 1 in the submenu by pressing ENTER, and the display shows as below: 3.1.1 Output Carrier 3.1.2 Attenuation 3.1.3 NIT Insertion 3.1.4 Output Stream...
Page 19
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 3.1.10 Srv Mask 255.255.255.000 3.1.11 Srv Gateway 192.168.000.001 3.1.12 Srv Mac Add 20141216131 The operation of output 2, output 3 and output 4 is the same as output 1. 4.2.4 Network Setting By pressing MENU button on the front panel, user can return to the main interface and then select item Network Setting by pressing ENTER to set the parameters.
Page 20
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 4.5.1 SCR IP Address 1 4.5.2 SCR IP Address 2 4.5.3 SCR IP Address 3 4.5.4 SCR IP Address 4 4.5.1 SCR IP Address 1 192.168.002.002 4.2.5 Saving configuration User can choose to save the current configured parameters by pressing ENTER key.
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 User can select the needed language at this submenu: 中文 *English Chapter 5 SNMS Setting Network Management System Profile Network management system is applied to digital TV equipment operation, control, management and parameters setting, etc. It centralizes digital TV equipment through network.
Page 22
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 User can login the NMS by pressing Confirm key after inputting user name and password. Upon the inputs, the software will verify them with database record automatically. If both of them are correct, the main interface will appear. Both of the default user name and password are admin.
Page 23
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.2.3 Adding Frequency Point The Add Freq Point dialog box popes up when the user clicks the Add Freq Point item in the Edit pull down menu on the menu row. User can also click right mouse key to pop up the short-cut menu in device tree or in the left blank column, then the Add Freq Point dialog box popes up by choosing Add Main Freq Point.
Page 24
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 menu on the menu row or clicks right mouse key to pop up the short-cut menu in device tree or in the left blank column, then the Add Equipment dialog box popes up by user’s choosing Add Equipment 5.2.5 Edit Equipment Interface...
Page 25
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 NOTE: The default IP of FUTV4443A is 192.168.2.1, also you can check its IP address in the front panel of device in case the IP changed unexpected. The NMS PC IP address and device IP address should be in the same network.
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 according to the loaded values by clicking Alternatively, user can also click the button on the toolbar to popup the “save file” dialog box, which gives prompts to save all the device’s parameters as binary files in the computer’s hard disk.
Page 27
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 User can select “Input setting” in the main interface. 5.3.1 Mux/Scrambler Setting In this field, users can set and get the device inputting parameters 5.3.1.1 Mux 6 Tuner input 4 ASI input Not applicable In this box, all 10 inputting ports(6 tuner input and 4 ASI input port) are displayed in...
Page 28
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 the left box. User can select any port and scan all the programs contained in each port by clicking PARSE button at the bottom left corner. Programs refresh input/out User can select the program to be multiplexd and click the arrow...
Page 29
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 target program and click Modify Prg button between the 2 boxes, then the modify interface pops out as shown above. User can select the item to be modified and input new information in the corresponding box below. To prosper the...
Page 30
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 IP Address This field means the scrambling IP address of the current outputting channels. The scrambling IP addresses of all modules in the network must be different, and the NMS IP addresses of all modules must be different. Otherwise, it will cause IP conflict, and the device will not work normally.
Page 31
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 After the modification, users can click the Confirm button to submit the current configuration, and click the Cancel to quit the current operation. 5.3.1.3 Transparent Transport Pass User can decide to bypass the inputting PID as needed in this interface. This interface can be used pass through the EPG table, STB update data, etc.
Page 32
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.3.1.4 Parameters User can set the output parameters in this interface, the display shows as below. 32 / 39...
Page 33
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 5.3.1.5 NIT NIT: Network Information Table. NIT table is a very important table for describing the network and TS. Users can set the parameters of the output NIT table as below. 33 / 39...
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 :The parameter describes the output TS’s network ID :The parameter describes the output TS’s network name Insertion private description : This checkbox will allow user to insert the private descriptor into the output TS. The private descriptor includes two parts. One is descriptor tag, and the other is descriptor information.
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Modulation standard J.83B Constellation: 64QAM/256QAM optional Symbol Rate range: 5.057 Msps Bandwidth:6M optional Modulation standard J.83C Constellation: 64QAM/256QAM optional Symbol Rate range: 2.5Msps~4.66Msps, 5.0Msps~8.0Msps,1ksps stepping Bandwidth:6M optional Out gain: attenuation ranges -25dBm~6dBm,0.5dB stepping 5.5 Real-time Monitor In this interface, users can monitor the code rate of inputting (256 IP optional) and outputting (1-8 optional) clearly.
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Prearrange Update time. 5.7 Parameters User can set the parameters in this interface, the display shows as below. 36 / 39...
Page 37
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 . It will pop up the following User can edit and insert PSI/SI by clicking interface: 37 / 39...
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Chapter 6 Troubleshooting This ISO9001 quality assurance system has been approved by CQC organization. For guarantee the products’ quality, reliability and stability. All our products have been passed the testing and inspection before ship out factory. The testing and inspection scheme already covers all the Optical, Electronic and Mechanical criteria which have been published by our company.
FMUSER INTERNATIONAL GROUP INC. 广州市汉婷生物技术开发有限公司 Chapter 7 Packing List FUTV4443A 4 IN 1 Mux-Scrambling QAM User’s Manual Tuner wire 5pcs ASI wire 4pcs Grounding wire 39 / 39...
Need help?
Do you have a question about the FUTV4443A-10 and is the answer not in the manual?
Questions and answers