Keep unauthorised persons at a safe distance from the working area. Persons within the working area are subject to the same dangers.
!
Remove ties, watches, rings, and other jewellery, and contain long hair.
!
DO NOT use the welder for any purpose other than for which it is designed.
%
DO NOT use the welder in damp or wet locations.
%
DO NOT stand welder on a metal workbench, car bodywork or similar object.
%
DO NOT touch any live metal parts of the torch or electrode while the machine is switched on.
%
DO NOT weld without a welding safety head shield, gauntlets, clothing, (see above warning).
%
I
DANGER! DO NOT weld near inflammable materials, solids, liquids, or gases, (see above warning).
s
DO NOT operate welder while under the influence of drugs, alcohol or other medication, or if you are fatigued.
%
DO NOT operate the welder if it or it’s cables are damaged.
%
DO NOT allow untrained persons to operate the welder.
%
DO NOT pull welder by the cable, or electrode holder. DO NOT bend or strain cables, protect from sharp or abrasive items. DO NOT stand
%
on cables or leads. Protect from heat. Long lengths of slack must be gathered & neatly coiled. DO NOT place cables where they endanger others.
DO NOT touch the electrode holder or workpiece immediately after welding as they will be very hot. Allow to cool.
%
DO NOT open the cover of the machine. Switch off machine and remove the plug from the power supply after use.
%
2.
DESCRIPTION & SPECIFICATIONS
HEAVY DUTY AIR-COOLED ARC
WELDER
The “XL” model is fitted with a heavy
duty air-cooled transformer. Features
include single vented wrap-around
shell fitted on heavy duty chassis,
carrying
handle
and
screw-type
stepless
welding
current
Supplied with a full accessory kit,
including electrode holder, earth clamp
and hammer/brush.
HEAVY DUTY TURBO COOLED
ARC WELDERS
Turbo Forced Air Cooling System, the
“XTC” range has increased duty cycle
and performance. Featuring single
vented wrap-around shells fitted to a
heavy duty chassis with wheels and
chassis
support
and
screw-type stepless welding current
control. Supplied with carrying handle
and extension bar for easy mobility.
Complete with full accessory kits
including electrode holder, earth clamp
chipping hammer and brush.
SUPER DUTY TURBO COOLED
ARC WELDERS
Models have Dual Voltage input,
allowing use on single phase 230V
input up to the maximum that can be
achieved on a 30 amp power supply.
Higher performance can then be
achieved by switching to 415V and
connecting to an appropriate supply.
Please consult an electrician. Model
250XT/DV also has Dual Voltage
output allowing use with wider range of
electrodes.
Model No.
Welding
Current
150XL . . . . . . . .40-150A . .Ø1.6-3.2mm . . .Air Cooled . . . .10mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.35 kVA
control.
Model No.
Welding
150XTC . . . . . . .40-150A . .Ø1.6-3.2mm . . .Turbo Fan . . . .16mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.35 kVA
a
160XTC . . . . . . . .55-160A . . . . .Ø2-4mm . . .Turbo Fan . . . . .16mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.98 kVA . . . . . . . .
200XTC . . . . . . . .55-200A . . . . .Ø2-4mm . . .Turbo Fan . . . . .16mm
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.98 kVA . . . . . . . .
Model No.
250XT . . . . .35-170A (230V) . . .Ø2-5mm . .Forced Air . . .25mm
. . . . . . . . . .50-250A (415V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 kVA . . . . . . .
250XT/DV . .32-170A (230V) . . .Ø2-5mm . .Forced Air . . .25mm
. . . . . . . . . .80-250A (415V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 kVA . . . . . . .
IMPORTANT INFORMATION
To operate all welders to their full capacity, you must run them on the correct power supply. To check the amperage,
use the following formula: kVA Rating x 4.35 = Correct Amps Supply
Electrode
Cooling
Capacity
Electrode
Cooling
Current
Capacity
Welding
Electrode
Cooling
Current
Capacity
Output
No-Load
Power Input/
Cable Ø
Voltage
Efficiency
. . . . . . .48V . . . . . .230V 1ph . . . .20 kg
2
Output
No-Load
Power Input/
Cable Ø
Voltage
. . . . . . .48V . . . . . .230V 1ph . . . .20 kg
2
. . . . . . .49V . . . . . .230V 1ph . . .21 kg
2
. . . . . . .52V . . . . . .230V 1ph . . .27 kg
2
Output
No-Load
Power Input/ Weight
Cable Ø
Voltage
. . . . .48V . .230V 1ph, 415V 3ph . .48 kg
2
. .48V/70V . .230V 1ph, 415V 3ph . .48 kg
2
Arc Welders - (0051) - (3) - 070601
Weight
Weight
Efficiency
Efficiency

Advertisement

loading

This manual is also suitable for:

150xtc160xtc200xtc250xt250xt/dv