Instructions for Use
MODEL 7070 NasoNeb® Sinus Therapy System
MODEL 7080 NasoNeb® Sinus Therapy System Supply Kit
Monaghan Medical Corporation
153 Industrial Blvd Plattsburgh, NY 12901 USA
Telephone: (800) 833-9653
www.nasoneb.com
English - US

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NasoNeb 7070 and is the answer not in the manual?

Questions and answers

Summary of Contents for Monaghan NasoNeb 7070

  • Page 1 Instructions for Use MODEL 7070 NasoNeb® Sinus Therapy System MODEL 7080 NasoNeb® Sinus Therapy System Supply Kit Monaghan Medical Corporation 153 Industrial Blvd Plattsburgh, NY 12901 USA Telephone: (800) 833-9653 www.nasoneb.com English - US...
  • Page 2 Table of Contents INTRODUCTION........... . .2 IMPORTANT SAFEGUARDS.
  • Page 3 IMPORTANT SAFEGUARDS READ ALL INSTRUCTIONS BEFORE USING WARNING – To reduce the risk of injury: • Use the NasoNeb® Sinus Therapy System only for its intended use as described in this manual. • Use only with NasoNeb-brand accessories. • Never drop or insert any object into any opening or hose. •...
  • Page 4 SET UP AND OPERATION Follow these simple steps to prepare and operate the NasoNeb® Sinus Therapy System. SETUP 1. Unpack the tubing. Connect one end to the outlet of the Insert NasoNeb® Compressor. 2. Unpack the NasoNeb® Sinus Therapy System and assemble by following these steps: a.
  • Page 5 The Compressor has a filter installed in the filter holder. There are additional filters included in the system. Check the filter every 6 months or 720 minutes of use. If it is dirty, replace the filter. Additional filters can be acquired from Monaghan Medical Corp. or where you purchased the NasoNeb® System.
  • Page 6 (the “Warranty Period”). This warranty is limited to the original purchaser of the NasoNeb® Sinus Therapy System and is non- transferable. Any defective parts or assembly will be repaired or replaced, at the sole discretion of Monaghan Medical Corp. if the unit has not been misused or tampered with during the Warranty Period.
  • Page 7 SPECIFICATIONS Specifications and appearance are subject to change without notice. Components may be substituted at the will of Monaghan Medical Corporation. NASONEB® Compressor Electrical DC 12V 1.5A, 180 VA Sound Pressure 55 dB Free flow 6 l/min nominal Compressor Pressure Range ≥200 kPa (≥29 psi)
  • Page 8 Manufactured by: Monaghan Medical Corporation Plattsburgh, NY 12901 1 (800) 833-9653 customerservice@monaghanmed.com NasoNeb and NasoNeb Logo are registered trademarks of Monaghan Medical Corporation. ©2016, 2022 Monaghan Medical Corporation. All rights reserved. 32101-00, AWN101-00...