Step 3.
Use [Up] / [Down] arrows to select a parameter to test.
Step 4.
Press [OK] to run test.
Step 5.
Press [ESC] to stop test at any time.
NOTE: Connected luminaires may not respond on the fi rst action (may delay) of the master luminaire.
MOVEMENT DISABLE
The Movement option allows pan and tilt to be disabled so that the luminaire can be placed in any position for
testing without movement occurring. In order to regain full control of the luminaire, Movement will need to be
enabled after testing.
NOTE: When using the Movement option, pan and tilt will be disabled for all the luminaires that are linked.
To set movement option:
Step 1.
Press [ESC].
Step 2.
Press [Up] /[Down] arrows until Confi g appears. Press [OK].
Step 3.
Press [Up] / [Down] arrows until Pan/Tilt appears. Press [OK].
Step 4.
Movement will be displayed. Press [OK].
Step 5.
Use [Up] / [Down] arrows to select Enable or Disable. Press OK] to select.

DIAGNOSTIC TESTS

The following diagnostic tests are available in the test menu. Press [Menu] at anytime to stop test.
TEST NAME
ALL Test ...................
Pan/Tilt .....................
Pan.....................
Tilt.......................
Intensity ..........
Color Flag Test ..........
Color Wheel 1 ..........
Color Wheel 2 ..........
Color Wheel 3 ..........

USB LOGGING

The VL1600 Profi le Luminaire stores error messages in a log fi le within the luminaire. This information along
with specifi c luminaire settings can be saved as a .csv (comma-separated values) fi le to a USB fl ash drive con-
nected to the USB port.
To save the current log fi le to a USB Flash Drive:
Step 1.
Insert a USB fl ash drive (not supplied, by others) into luminaire's USB port.
Step 2.
Step 2. Press [ESC].
Step 3.
Press [UP] / [DOWN] arrows until Fixture appears. Press [OK].
Step 4.
Press [UP] / [DOWN] arrows until USB appears. Press [OK].
Step 5.
Press [UP] / [DOWN] arrows until USB Log appears. Press [OK].
Step 6.
Press [UP] / [DOWN] arrows until DOWNLOAD appears. Press [OK].
Step 7.
Once the download is complete, the display will read "Reset Current Lum
error lognfi le?" Press [OK] to reset or [ESC] to exit.
Step 8.
Press [OK] to clear the current log fi le in the luminaire or [ESC] to keep it.
The .csv log fi le on the USB Flash Drive can be read via any computer system. The fi le name will be as follows:
26KSxxxxx.csv (the xxxxx will be the unique luminaire ID of the fi xture). Each log fi le contains labels and values
as shown below.
DISPLAY
Running 'ALL TEST'
Running 'PAN TILT TEST'
Running 'PAN TEST'
Running 'TILT TEST'
Running 'INTENSITY TEST'
Running 'COLOR FLAG TEST'
Running 'CW 1 TEST'
Running 'CW 2 TEST'
Running 'CW 3 TEST'
32