Features & Specifications ● Product Name: Bluetooth Digital Food Thermometer ● Product Model:IHT-2PB ● About 328 feet (100 meters) of Bluetooth controlling range in an open field ● 3 stainless steel probes for temperature measuring ●...
Connection Free App Download Get INKBIRD APP from Google Play or App Store for free, or you can scan the QR codes below to download the app directly. INKBIRD APP Please make sure the following requirements are met to download the apps smoothly: -Your devices must be running IOS11/Android 5.0 or above to download the app.
Page 7
Now you can add the device needed. Click “+” in the top right corner to add the device. - 04 -...
Page 8
Turn on the device. Make sure the Bluetooth icon is flashing. Search for device, please ensure that the equipment is within 10 meters. - 05 -...
Page 9
APP matching: The devices need to authorize the match. Click the SET button of the device IHT-2 PB to agree on authorization and allow the application to match the device. Connect successfully. - 06 -...
Key Definition Press and hold the button for 2 seconds to enter the menu for function setting. During the setting process, press the button to choose functions; press and hold the button for 2 seconds to quit and save setting changes. Press the button to turn on the device.
Page 12
Setting Menu ● Setting Device More Temperature unit ℃ ℉ Key sound Screen backlinght time Temperature correction ℉ ℉ ℉ - 09 -...
Page 13
More Settings ● Setting Device More Need a pop-up notification about temperature? Modification of equipment name Ink@IHT-2PB#366 REMOVE THE DEVICE vision 62:00:A1 1.0.8 :1C:4F: - 10 -...
Menu Instruction MENU DIS- SETTING DEFAULT FUNCTIONS ITEMS PLAY RANGE VALUES Celsius/ Fahrenheit Key sound ON or OFF Backlight 5~60S active time Alarm function ON/OFF for the built-in probe -50.0℃~300℃ 77.0℃ Alarm value for the built-in probe -58.0℉~572℉ 170℉ -4.9℃~4.9℃ 0.0℃...
Parameter Setting Guide Temperature Display Unit of ℃/℉ Step 1: press and hold button for 2 seconds to enter the menu for function setting, then press the button to choose CF function. Step 2: press button to choose ℃ or ℉. NOTE: All parameters will be restored to their default values once you change the temperature unit.
Page 16
Step 3: press and hold button for 2 seconds to quit and save changes. (All changes will be automatically saved if there is no operation in 30 seconds.) Backlight Active Time Step 1: press and hold button for 2 seconds to enter the menu for function setting, then press the button to choose BLT function.
Page 17
Step 2: press button to choose ON or OFF. Step 3: press and hold button for 2 seconds to quit and save changes. (All changes will be automatically saved if there is no operation in 30 seconds.) Alarm Value Setting for the Built-in Probe Step 1: press and hold button for 2 seconds to enter the menu for function setting, then press the button to...
Page 18
Step 2: press button to increase or decrease the value; long press to quickly increase or decrease the value. Step 3: press and hold button for 2 seconds to quit and save changes. (All changes will be automatically saved if there is no operation in 30 seconds.) When the current temperature is 75.5℉, the screen displays 75.8℉...
Page 19
Step 1: press and hold button for 2 seconds to enter the menu for function setting, then press the button to choose TS1 function. Step 2: press button to increase or decrease the value; long press to quickly increase or decrease the value. Step 3: press and hold button for 2 seconds to quit and save changes.
Page 20
When the current temperature is 75.5℉, the screen displays 75.8℉ after setting the CA1 value as 0.3℉. Alarm Function for P2 (the External Probe 2) Step 1: press and hold button for 2 seconds to enter the menu for function setting, then press the button to choose ALM2 function.
Page 21
Step 2: press button to increase or decrease the value; long press or to quickly increase or decrease the value. Step 3: press and hold button for 2 seconds to quit and save changes. (All changes will be automatically saved if there is no operation in 30 seconds.) Temperature Calibration for P2 (the External Probe 2) Step 1: press and hold...
When the current temperature is 75.5℉, the screen displays 75.8℉ after setting the CA2 value as 0.3℉. Operating Functions Of The Built-In Probe (unplugging the external probes) Screen Display Without plugging the external probes, the built-in probe is the current channel. The LCD screen displays data of the current channel in priority.
Page 23
Turn ON/OFF Automatically: The device is automatically turned on by unfolding the built-in probe. It is turned off when you fold the probe back. Manually: Press button to turn on the device. Regardless of the probe being folded or unfolded, you can press and hold button for 2 seconds to turn off the device.
Backlight Backlight helps you check data conveniently. Without any operation, the backlight will keep activated for the time of BLT parameter, then be off automatically . You can press any button to activate it when it’s off. If you unfold the probe, the backlight will be activated automatically when the probe detects a temperature change.
Page 25
When you plug the external probe P2, the P2 probe is the current channel. The LCD screen displays data of the current channel in priority. P2 symbol appears on the screen. When ALM2=ON (the alarm function of P2 probe is on),the screen displays SET TEMP and the alarm value of P2probe.
Page 26
Alarm 1&2 Function When you set ALM1 (or ALM2) as OFF, the alarm function of P1 (or P2) probe is off, and the screen only display the current measured temperature. When you set ALM1 (or ALM2) as ON, the alarm function of P1 (or P2) probe is on, and the screen displays the alarm value of P1(or P2) probe (TS1/2) and the current measured temperature.
Display Switch Over Press and hold button for 3 seconds to switch to display data of the built-in probe. The screen will automatically return to display data of the current channels in 20 seconds if there is no more manual switchover.
contact with the P2 jack. contact with the P2 jack. If the display problem is still unsolved, or the screen If the display problem is still unsolved, or the screen displays “Er2”, please contact INKBIRD. displays “Er2”, please contact INKBIRD. Q4: Why can’t you turn on/off the thermometer by Q4: Why can’t you turn on/off the thermometer by folding/unfolding the probe?
microwave ovens. microwave ovens. ● Please do not use the product beyond the temperature ● Please do not use the product beyond the temperature range from -50℃ to 300℃ (-58℉ to 572℉), or it may cause range from -50℃ to 300℃ (-58℉ to 572℉), or it may cause damages.
Page 30
pursuant to Part 15 of the FCC Rules. These limits are pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against designed to provide reasonable protection against harmful interference in a residential installation. This harmful interference in a residential installation.
Need help?
Do you have a question about the IHT-2PB and is the answer not in the manual?
Questions and answers