EN 32
9.
FTP2.4E AB
9.4
PNx83xx MOJO
The MOJO is a source decoder chip targeted for very low cost
application in integrated digital televisions.The device contains
all hardware and software to be able to decode and display
MPEG2 transport streams, including:
Descrambling.
Demultiplexing.
Audio / video decompression.
Video encoding.
Overlay graphics provisions.
Some features of the MOJO are:
32-bit PR1910 core operating at 120 MHz.
16-bit memory and peripheral interface to connect ROM.
NOR Flash and various peripherals.
Sixteen external interrupt inputs shared with PIO lines.
Several embedded peripheral units with physical interfaces
to:
Two UART (RS-232) data ports.
2
Two I
C master / slave transceivers.
Two smart-card reader interfaces.
One Integrated Conditional Access Module interface.
Supports parallel and serial transport stream input
interfaces.
9.5
Front End
The front end of the "IBO Zapper" module is almost identical to
the "IBO+" module as used in the A10E with the exception that
the Transport Streams that come from the COFDM
demodulator are now fed through the PCMCIA controller first.
The PCMCIA controller receives encrypted Transport Streams
from the COFDM demodulator. Via the PCMCIA card, these
encrypted Transport Streams are decrypted, and transported
to the MOJO.
9.6
Back End
The MOJO is the main building block of the back-end of the
"IBO Zapper" module. The IC decodes the MPEG-2 stream into
analogue video and digital audio.
9.6.1
Transport Stream Input
The Transport Stream input is according to MPEG2 standard.
In the "IBO Zapper", only 8-bit parallel is supported. The used
TS names are TDA_DATA.
9.6.2
Video Outputs
The MOJO has two analogue video outputs:
Primary (TV): YUV + RGB.
Secondary (VCR): CVBS.
The primary MOJO output is used as input for the TV display
and is fed to the HIP RGB inputs. The signal path is as follows:
switch 7I12 chooses between the SCART1 input signal and the
RGB output of the MOJO.
The secondary MOJO output, which delivers CVBS signals, is
used for monitoring purposes or for recording via the SCART 2
output of the TV set. The signal path of the secondary MOJO
output is as follows: the CVBS/VCR signal coming from the
MOJO is sent to the HIP video switch input, pin 23. The signal
then appears on one of the outputs of the HIP video switch, pin
34, and is passed on via buffer 7415 to pin 19 of SCART 2,
which is the CVBS/monitor output.
For further details, see the manuals of the original TV sets on
which the various models of IBO zappers are based.
All manuals and user guides at all-guides.com
Circuit Descriptions, Abbreviation List, and IC Data Sheets
9.6.3
9.7
9.8
9.9
9.10 Power Supply IBO Zapper Module
9.10.1 Off State
9.10.2 Passive Stand-by State
9.10.3 Active Stand-by State
Audio Outputs
The MOJO has two audio output interfaces:
SPDIF Out: The SPDIF sound output goes directly to a
connector on the back of the module.
I2S Out: This digital sound output is fed through a DAC and
the analogue L/R signals are directly fed via the source
selector (item 7I17) into the Audio Demodulator (item
7A02).
IBOLink Interface
The IBOLink™ approach is such that the conventional TV
microcontroller is re-used when digital functionality is added. In
principle, the TV can still operate without the bolt-on module.
The IBOLink™ software is added to the TV-set software, and is
operating as a software bridge.
Control Interface
The "IBO Zapper" is connected as a slave I
bus should be +5V tolerable and operating at 100 kHz (max).
The "IBO Zapper" module slave address is 0xE4 (similar to
IBO+) but is configurable via IBOLink.
All communication from digital module to Television chassis
has to be initiated via an active low hardware interrupt line from
the digital module.
UART Interface
The UART interfaces (Universal Asynchronous Receiver And
Transmitter) are serial interfaces, which are used to transfer
data and commands between two devices.
The "IBO Zapper" system uses an UART interface for serial
communication with a pc for:
Diagnostic SW for Service or Production.
SW uploading for Service or Development.
The "IBO Zapper" module operates from a single 12 V supply
provided by the TV chassis. All other voltages that the module
needs are derived from the +12V. The module has four
different physical power states:
"Off" State.
"Passive Stand-by".
"Active Stand-by".
"On" State.
The TV set is powered "off" via the main power switch. The
module is not powered.
The TV set is in "Stand-by" mode. The module is in "off" state.
The TV set is in "Semi-Stand-by" mode. All the circuits in the
set, except the audio output and the display are powered up
and fully active. The set appears to be in normal "Stand-by"
mode for the customer.
The module is in "On" or "Logical Stand-by" state.
2
2
C device, The I
C

Advertisement

Table of Contents
loading

Table of Contents