Troubleshooting
1 The Pulse indicator light is flashing, but the electric shock delivered by the fence is weak.
Check that the energiser is adequate for the length of the fence. If necessary, reduce the length of
the fence or reduce the number of fence wires. Alternatively, divide the fence-line into smaller
zones, with each zone powered by a separate energizer.
2 The Pulse indicator light is not flashing, Battery is not connected properly, or battery is dead flat
3 The battery needs frequent replacement.
Check that the solar panel is clean and is not damaged. Make sure the energiser is positioned to
receive maximum sunlight. If necessary, remove any objects or vegetation that might be casting a
shadow on the energizer.
4 After the energiser is switched on, the pulse indicator light gives three long permanent flashes,
and then the energiser appears to be off, the battery is very low and needs recharging.
5. Maintenance
Warning: Do not open or attempt to repair or modify, as warranty will be voided.
Fault
Solution
The Pulse indicator
Check that all connections in the fence and earth system are firm and
light is flashing, but
secure. If necessary, clean away any corrosion.
the electric shock
Check that the earth rod is pushed firmly into firm ground.
delivered
by the
Check for faults in the fence-line caused by trees or vegetation. If
fence is weak.
necessary, remove obstructions and mend the fence.
Check that the energiser is adequate for the length of the fence. If
necessary, reduce the length of the fence or reduce the number of fence
wires. Alternatively, divide the fence-line into smaller zones, with each
zone powered by a separate energizer.
Check that the energiser is switched on.
If there has been insufficient sunlight to charge the battery, the
energizer may be in Battery protection mode. Charge the battery by
placing the energizer in full sunlight with the solar panel facing true
The Pulse indicator
north in the southern hemisphere.
light is not flashing.
Ensure the battery is connected correctly with the positive (red) lead to
the positive(+) terminal on the battery and the negative (black) lead to
the negative (–)terminal on the battery.
Try charging the battery manually using a suitable battery charger.
Replace the battery with a new battery. Before installing a new battery,
charge it fully using a suitable battery charger.
If the pulse indicator light is still not flashing, return the energizer to the
dealer