Battery information

Battery charging
The solar panel can fully charge a flat battery in three days, provided the energiser is switched off
and there is adequate sunlight. The battery can also be charged using a 14.4V battery charger
suitable for charging rechargeable lead-acid batteries. This should have an output voltage of 14.4V
and output current not exceeding 1A. Charging can be carried out two ways, buy removing the
battery and charging or by plugging the correct charger directly into the unit at the DC Charging
The energiser must not be
point, this should be carried out with the energiser switched off.
connect to the fence when charging from a mains powered charger.
When fully charged, the battery should be able to power the energiser for three weeks (S1600
model) and two weeks (S4000 model) with no sunlight.
Replacing the battery
If a replacement battery is required, use a 12V, 4.5Ah, rechargeable lead-acid battery (suitable for
both models). Replacement Daken Part number is 70303D. Do not use a non-rechargeable battery.
Do not dispose of the battery in a land-fill or in a fire.
In the event of a spill or leakage from a lead-acid battery:
Contain small spills with dry sand, earth and vermiculite. Do not use combustible materials. If
possible, carefully neutralise spilled acid with soda ash, sodium bicarbonate, lime, etc.
Wear acid-resistant clothing, boots, gloves and a face shield.
Do not let acid get into the sewerage system.
Neutralised acid must be managed in accordance with approved local, state and federal
requirements. Consult your state environmental agency and/or federal EPA.
Energiser maintenance
Clean the solar panel regularly with a soft cloth using glass cleaner or a mild solution of detergent
and water. This ensures the solar panel functions efficiently.
When transporting the energiser, protect the solar panel to prevent the glass surface from being
damaged.
Energiser storage
If the energiser is stored for an extended period, the battery may discharge and become damaged.
The energiser should be stored inside, next to a window, where sunlight can shine on the solar
panel each day.
If the energiser cannot be stored in a sunny position, it should be kept in a cool place. The battery
should be fully charged and disconnected from the energizer. The battery should be recharged
manually every six months using a suitable 12 V battery charger.