  • Page 1 Ultrasonic humidifier Airbi TWIN Instruction manual (version 1.3) Page 1 of 11...
  • Page 2: Before First Use

    1 Before first use 1.1 Why humidify the air? Stay in heated rooms can be not only unpleasant, but also insanitary. One of the main reason is low humidity. Optimal humidity is between 45% and 60%, while in many of our homes in winter humidity drops below 20%.
  • Page 3  Do not shake the humidifier. This could spill water into the base unit and affect its operation.  Do not leave the humidifier in the sun for a long period.  If an unusual odour occurs during normal use, turn off the appliance, unplug it and have it verified by qualified personnel.
  • Page 4: Technical Specifications

    2 Description 2.1 Technical specifications Model: SPS-702 Evaporation rate: 120-300 ml/h Water tank capacity: 5 litres Ions production: 3 000 000 ions/cm3 Ozone production: < 0,05 ppm (according EU limits) Dimensions (H x W x D): 33,5 x 15 x 28,5 cm Weight: 2,6 kg without water Color: black, white Noise level: <...
  • Page 5 Ceramic filter to soften and purify the water. Three moisture control settings. Timer settings to ensure 1-12 hours of running time. Releases abundant anion, promotes cellular metabolism, increases vitality and appetite, purifies blood and soothes one's nerve. Easy to refill water into the water tank Increase and regulate relative humidity of the room air.
  • Page 6: How To Use

    3 How to use 3.1 Device control The device can be controlled by five buttons located on the front panel under the display. LCD Display ON/OFF – button switching on/off appliance ANION – button switching on/off ionizer and water tank's light MAX/MIN –...
  • Page 7: Getting Started

    The LCD display shows the measured values of temperature and humidity around the device and the other symbols for the different functions of the device. Description of all segments on LCD display: 15. mist volume 16. temperature ( 17. timer 18.
  • Page 8 humidity level in the room reaches the set humidity level, the machine will go into automatic sleep state and stop producing mist. When the room’s actual humidity level drops below your set humidity level then the machine will start producing mist again. You can deactivate automatic mode very easily by pressing the humidity button until you reach 75% RH.
  • Page 9: Troubleshooting

    4 Troubleshooting Trouble Possible reason Solution Power lamp off, humidifier No power supply Connect power supply, does not work switch on Power lamp on, no mist No water in water tank Fill water into water tank outlet with wind Abnormal smell mist New unit Take out water tank, open cover, let it stay 12 hours in...
  • Page 10: Maintenance

    5 Maintenance In case when the water is hard which means water contains too much calcium and magnesium, they can cause “white powder” problem and give heavy scum on the surface of water basin, transducer and inner surface of the water tank. Scum on the surface of transducer will make the unit work improperly.
  • Page 11: Disposal Of The Device (Environment)

    6 Disposal of the device (environment) At the end of the product lifecycle, you should not throw this product into the normal household garbage but bring the product to a collection point for the recycling of electrical and electronic equipments. The symbol on the product, user guide and/or box indicate this.