Available languages

✔ The temperature indicator LEDs for 11 °C (51 °F)
and 14 °C (57 °F) light up permanently.
➤To demonstrate the temperature setting func-
tion or the presentation mode, press the
button once.
✔ The temperature indicator LEDs for 11 °C (51 °F)
and 14 °C (57 °F) turn off within 2 seconds.

Troubleshooting

Fault
The device does not cool. Tempera-
ture indicator LEDs do not glow.
The device does not cool (plug is
inserted). Temperature indicator LEDs
glow.
The device does not cool (plug is
inserted). Temperature indicator LEDs
for 11 °C (51 °F) and 14 °C (57 °F) light
up permanently.
The interior LED lamp stays on perma-
nently even when the wine cooling
drawer is closed.
The device does not cool sufficiently.
Temperature indicator LEDs glow.
The upper temperature indicator LED
flashes repeatedly for 1 time.
The upper temperature indicator LED
flashes repeatedly for 3 times.
The upper temperature indicator LED
flashes repeatedly for 4 times.
The upper temperature indicator LED
flashes repeatedly for 5 times.
The upper temperature indicator LED
flashes repeatedly for 6 times.
✔ The temperature indicator LED of the last
selected temperature level lights up.
➤To deactivate the demo mode, press the
page 4).
✔ All temperature indicator LEDs flash for 3 times.
✔ The temperature indicator LED of the last
selected temperature level lights up.
Possible cause
No voltage present in the AC
voltage socket.
The cooling element is defective. ➤ Contact authorized service agent
The demo mode is activated.
The presentation mode is acti-
vated.
The cooling element is defective. ➤ Contact authorized service agent
The ventilation is insufficient.
The temperature sensor is defec-
tive.
The inner fan is defective.
The outer fan is defective.
The drawer is opened for too
long.
The drawer is not closed prop-
erly.
The compressor is defective.
4445103702
button for at least 6 seconds (fig. 6,
Suggested remedy
➤ Try using another plug socket.
for repair.
➤ Switch off the demo mode (fig. 6,
page 4).
➤ Switch off the presentation mode
(fig. 5, page 4).
for repair.
➤ Remove any obstruction or soiling
from the inlet and outlet vents.
➤ Contact authorized service agent
for repair.
➤ Contact authorized service agent
for repair.
➤ Contact authorized service agent
for repair.
➤ Close the drawer.
➤ Close the drawer properly.
➤ Contact authorized service agent
for repair.
9