Troubleshooting

Fault
No output voltage at battery terminal Battery is locked.
Battery recharge is not possible.
Battery capacity seems reduced.
I

Cleaning and maintenance

The lithium batteries are maintenance-free.
➤Occasionally clean the product with a damp
Possible cause
Wrong DIP-switch settings.
Wrong wiring polarity.
Low battery voltage.
Battery overheated.
Battery circuit shorted or over-
loaded.
Wrong DIP-switch settings.
Temperature sensor connector is
unplugged.
Battery temperature below 0 °C
Battery overheated.
Long storage
4445103613
NOTE
It's strongly recommended to use a bat-
tery monitor together with the LiFePO4
battery.
cloth.
Solution
Remove the transportation lock
fig. 1
(
Set the correct DIP-switch order.
(chapter "" on page 7)
Connect the battery properly.
Charge the battery for minimum 24h.
Wait 30 minutes to cool down the
battery and reset itself.
Plug the transportation lock in, wait
10 seconds and remove the transpor-
tation plug.
Disconnect all the cables from the
battery, wait 10 seconds and recon-
nect the cables.
Charge the battery to reset.
Set the correct DIP-switch order.
(chapter "" on page 7)
Connect the temperature sensor
connector properly.
Warm up the battery.
Wait 30 minutes to cool down the
battery and reset itself.
Charge the battery for minimum 24h.
, page 3).