ODORGAS
Digital instrument for Odorant measurement.
For professional use only
OMODORGAS Iss 01
Page 1 of 20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ODORGAS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for QED ODORGAS

  • Page 1 ODORGAS Digital instrument for Odorant measurement. For professional use only OMODORGAS Iss 01 Page 1 of 20...
  • Page 2: Table Of Contents

    Contents EU Declaration of Conformity ................3 Warnings ATEX ....................4 General Description ................... 4 Safety Instructions .................... 5 Overview of the instrument ................. 6 User Interface .................... 6 Battery Charger Connections ................7 Display ..................... 7 Instrument functions ..................8 Switch On ....................
  • Page 3: Eu Declaration Of Conformity

    E U D e c l a r a t i o n o f C o n f o r m i t y OMODORGAS Iss 01 Page 3 of 20...
  • Page 4: Warnings Atex

    With an internal memory for data storage of up to 3,000 readings, size of 145 x 70 x 33 mm / 5.7 x 2.75 x 1.3 inches and a weight of 350g / 12.34 Oz, the ODORGAS is an excellent and convenient instrument for measuring odorants.
  • Page 5: Safety Instructions

    Repair and maintenance of this equipment should be carried out in accordance with the applicable code of practice and this operating manual. Only QED approved components are to be used with this equipment. OMODORGAS Iss 01 Page 5 of 20...
  • Page 6: Overview Of The Instrument

    O v e r v i e w o f t h e i n s t r u m e n t User Interface Description ON/OFF button + Backlight + Enter key Function button Scroll Key Buzzer LED Alarm Lights ●●...
  • Page 7: Battery Charger Connections

    Battery Charger Connections The ODORGAS comes complete with its own charging base. Simply locate the ODORGAS into the charging cradle and switch on the power supply. Display SECTOR DESCRIPTION Pump status Battery status Unit of measurement Odorant type Measurement of Odorant...
  • Page 8: Instrument Functions

    ●● blink and the alarm will sound. The ODORGAS is now ready for use. Switch OFF Press and hold the ON/OFF key for a few seconds. A counter on the display will count down from 4 to 0 and the instrument will then power down.
  • Page 9: Taking Readings

    T A K I N G R E A D I N G S Measuring and storing readings To begin the measurement process, press and hold the function key. The screen will display these symbols. Press the ON/OFF key to begin the measurement process.
  • Page 10 The user will be prompted to save the reading against identification number. At the identification number prompt, the digit ready to be altered will flash. To change the number, use the scroll key. To move to the next number, use the function key.
  • Page 11: Recommended Accessories

    RC-1 Order Reference Number H-900035 Connect your RC-1 between your sample point and your Odorgas unit as per the diagrams below: Odorsoft Download PC software. H-707068...
  • Page 12 For downloading and exporting of all collected Odorgas data. Please contact sales@qedenv.co.uk for more information. OMODORGAS Iss 01 Page 12 of 20...
  • Page 13: Function Key Menu

    F u n c t i o n K e y M e n u User calibration Press and hold the left function key until ‘INIT’ appears. Use the right scroll key to reach ‘PASS’ then press ON/OFF key to select. Enter the default passcode ‘1001’...
  • Page 14: Escape Option

    Allow the instrument to reset to zero gas reading. Press and hold the left function key until ‘INIT’ appears again. Use the right scroll key to find ‘TEST’ screen. The Instrument will say test fail or test pass depending on whether the result is within tolerance.
  • Page 15: To Alter The Passcode

    To store the passcode use the ON/OFF key. W A R R A N T Y The QED Warranty terms and conditions for the Odorgas can be found on the QED website in the downloads section, or alternatively by using the link below & searching ‘warranty’.
  • Page 16: Appendix A - Safe Use Of The Instrument

    The information contained in these safety instructions must be followed in addition to the warnings in the user manual supplied to the customer. WARNING: Do not use the instrument ODORGAS in a classified area if the version of the apparatus is not certified ATEX.
  • Page 17: Repair

    Repair In the event of malfunction or damage, please contact QED (or an authorised distributor) for support. Conformity The apparatus type ODORGAS is usable in gas explosive atmosphere of group IIC and temperature class T4 for an ambient temperature from -20°C to +40°C.
  • Page 18: Appendix B - Technical Specifications

    A P P E N D I X B – T e c h n i c a l S p e c i f i c a t i o n s Target gas TetraHydroThiophene (THT) Measurement ranges Minimum threshold Accuracy +/-10% relative to reading Environmental working...
  • Page 19: Appendix C - Information On Disposal For Users Of Waste Electrical & Electronic Equipment

    Note: When your instrument is at the end of its life, please contact your local distributor, or our sales team at QED on +44(0)333 800 0088 or email sales@qedenv.co.uk, who will advise you on the next step in order to help us meet our obligations.
  • Page 20 QED Environmental Systems Cyan Park, Unit 3 Jimmy Hill Way Coventry CV2 4QP United Kingdom sales@qedenv.co.uk...