Interferences; Notes - RAPA E Original User Manual

Table of Contents

Advertisement

11. INTERFERENCES

The most often occurring interferences of the device operation:
Reasons
Contaminated
Visible dust layer on the condenser fins,
>
condenser
hot air coming out of the aggregate chamber,
>
>
loud operation of the aggregate,
characteristic "clicking" coming out of the
>
aggregate chamber every few minutes
Device loaded with
hot air coming out of the aggregate chamber,
>
warm products
>
loud operation of the aggregate,
>
characteristic "clicking" coming out of the
aggregate chamber every few minutes
Too high ambient
>
hot air coming out of the aggregate chamber,
temperature
loud operation of the aggregate,
>
characteristic "clicking" coming out of the
>
aggregate chamber every few minutes
Improper goods
>
temperature on exposition is too high;
distribution in
temperature in storage area is too low.
>
cooling chamber
External source of
hot air coming out of the aggregate chamber,
>
heat causing the
>
loud operation of the aggregate,
abnormal
characteristic "clicking" coming out of the
>
operation of the
aggregate chamber every few minutes
device

12. NOTES

1. Attempts to repair the device on your own and not following the instructions
described in the user manual as for equipment connection and use will result
in the device malfunction.
2. The device is using natural and ecological refrigerant R-290 (propane).
3. The manufacturer is not liable for damages resulting from the use of the device
in a manner inconsistent with the information contained in hereby user manual.
Symptoms
Warning! In case of damage of the cooling system the refrigerator
should be immediately disconnected from the mains, any open
sources of fire located close to the unit removed and the area
carefully ventilated.
Do not use electrical appliances inside the refrigerator.
15
Solution
Before cleaning of the condenser it is
necessary to switch the device off.
Impurities on the condenser should be
removed by means of vacuum cleaner
equipped with brush, gently along fins to
not to bend the lamella.
Goods loaded in the device chamber should
be initially cooled up to maximum +4°C above
the storage temperature .
Ambient temperature for proper operation of
the device should not exceed respectively: for
rd
3
climatic class +25°C.
The goods should be placed as described in
user
manual.
External source of heat might be any other
device that emits heat such as gas burner,
heater, other device equipped with a
refrigerated aggregate etc. It is necessary to
pay attention if above mentioned examples
may have influence on the deterioration of
device operation conditions.

Advertisement

Table of Contents
loading

This manual is also suitable for:

E maxE1E1 maxFF max