Flexitron Taxitronic TX80 URBA ONE Installation Manual

Flexitron Taxitronic TX80 URBA ONE Installation Manual

Hide thumbs Also See for Taxitronic TX80 URBA ONE:

Advertisement

Quick Links

INSTALLATION MANUAL TX80 URBA ONE
INTERFACOM, S.A.U. 02/03/2022
INSTALLATION MANUAL
TX80 URBA ONE
Inst TX80_urba_one_003_EN.doc
13/10/2021

Advertisement

Table of Contents
loading

Summary of Contents for Flexitron Taxitronic TX80 URBA ONE

  • Page 1 INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. 02/03/2022 INSTALLATION MANUAL TX80 URBA ONE Inst TX80_urba_one_003_EN.doc 13/10/2021...
  • Page 2: Table Of Contents

    INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. TABLE OF CONTENTS INTRODUCTION ........................3 INSTALLATION ........................3 2.1. TX80 URBA ONE LOCATION AND INSTALLATION ............3 ELECTRICAL INSTALLATION ....................4 SEALING ..........................8 TECHNICAL CHARACTERISTICS ..................9 IMPULSE GENERATOR ...................... 10 6.1.
  • Page 3: Introduction

    INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. 1. INTRODUCTION The focus of this document is the description of the TAXITRONIC TX80 URBA ONE right installation. the order in which the equipment installation and programming must be carried out is established.
  • Page 4: Electrical Installation

    INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. 4. Once located and oriented, the lateral screw of the bracket must be tightened until the equipment is fixed. 3. ELECTRICAL INSTALLATION The TX80 URBA ONE Has the following connectors: • (1) Power supply Contact number Colour Function...
  • Page 5 INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. • (2) Serial Rooflight The connector on the cable has a white mark, which must be visible from the connectors cover. Contact number Function + 12V TTL 0 – 5 V TTL 0-5 V •...
  • Page 6 INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. • COMPLETE INSTALLATION Inst TX80_urba_one_003_EN.doc...
  • Page 7 INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. RECOMMENDATIONS FOR THE ELECTRICAL INSTALLATION Disconnect the positive terminal on the battery until the whole electrical installation is completed. Any manipulation of the taximeter or of the external lights must be done while the taximeter is disconnected from the power supply Always take the positive and negative directly from the battery in order to avoid false contacts and to obtain a more filtered power supply.
  • Page 8: Sealing

    INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. 4. SEALING - Seal Nº 1: Seals the taximeter box, preventing access to the electronic board. - Seal Nº 2: Seals the connectors cover, so it seals the electrical installation and the tariff connector.
  • Page 9: Technical Characteristics

    INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. 5. TECHNICAL CHARACTERISTICS The general technical characteristics of TX80 URBA ONE are as follows: Supply voltage: Nominal = 12 V Max = 30 V Min = 8 V − Maximum consumption without external lights = 300 mA −...
  • Page 10: Impulse Generator

    INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. 6. IMPULSE GENERATOR 6.1. INTRODUCTION − For the vehicles with mechanical speedometer, you have to use a pulse generator that is managed by the taximeter. − The pulse generator is inserted in the cable of the speedometer and converts the mechanical movement of this cable in an electrical signal, which is amplified and filtered by the taximeter.
  • Page 11 INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. − Finally, all pieces are assembled by screwing together the two fixing rings taking into account that the separating space indicated by (8) must be sufficient. Inst TX80_urba_one_003_EN.doc...
  • Page 12: Cable Connection, Cover Closing And Pulse Generator Support

    INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. 6.2.2. CABLE CONNECTION, COVER CLOSING AND PULSE GENERATOR SUPPORT − To connect the pulse generator cable, it is necessary to open the pulse generator cover (item 1) after taking the closing screw out and moving the cover in the right direction indicated by the arrow.
  • Page 13: Sealing

    INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. 6.3. SEALING − The pulse generator installation can also be sealed, as shown in the image. 6.4. TECHNICAL CHARACTERISTICS − The main technical characteristics of the pulse generator are: − Sensor type: Hall effect cell −...
  • Page 14: Error Messages

    INSTALLATION MANUAL TX80 URBA ONE INTERFACOM, S.A.U. 8. ERROR MESSAGES − The possible error messages that may appear on the display are listed below. E-2 Roof lights failure: The roof lights are not correctly connected or some of its bulb lights doesn’t work. This error is shown if it is enabled in the tariff. E-5 The taximeter is out of the configured revision period: This message is shown when the taximeter is out of the configured revision period.