About this document

1.1

Applicable documents

All available documents for the product è www.festo.com/sp.
Type
Product
Integrated drive
EMCS-ST
Integrated drive
Drive system
EGSS-BS
Mini slide unit
ELGE-TB
Toothed belt axis unit
ELGS-BS
Spindle axis unit
ELGS-TB
Toothed belt axis unit
EPCS-BS
Electric cylinder unit
Drive
EGSC
Mini slide
ELGR-TB
Toothed belt axis
ELGC-BS
Spindle axis
ELGC-TB
Toothed belt axis
EPCC-BS
Electric cylinder
Mounting kit
EAMM
Axial and parallel kit
IO-Link cable
NEFC
Adapter
Tab. 1: Applicable documents for the product
1.2

Product version

This documentation refers to the following datasets:
– Firmware version of the integrated drive from "v19.0.4.107_release"
– IO-Link device description file (IODD) from V1.2.6
– Adapter NEFC from production date 01/2022
If a different firmware version is used, check whether there is a correspondingly
newer version of the documentation è www.festo.com/sp.
1.3

Product labelling

1
Fig. 1: Product labelling
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Deutschland
+49 711 347-0
www.festo.com
Contents
Manual
Operating instructions
Operating instructions
Operating instructions
Operating instructions
Operating instructions
Operating instructions
Operating instructions
Operating instructions
Operating instructions
Operating instructions
Assembly instructions
Assembly instructions
1
Product labelling (product information,
approvals, warning symbol)
Warning symbol
Warning
Meaning
symbol
Attention! Hot surface
Metallic housing parts of the device can reach high temperatures during operation. In
the event of a fault, internal components may become overloaded.
Tab. 2: Warning symbol
1.4

Specified standards

Version
IEC 60204-1:2005+AMD1:2008 CSV
IEC 61131-2:2013
EN 61800-2:2016
Tab. 3: Standards specified in the document
2
Safety
2.1

Safety instructions

– Only use the product if it is in perfect technical condition.
– Only use the product in its original condition without unauthorised modifica-
tions.
– Do not carry out repairs on the product. Replace defective product immediately.
– Observe the identifications on the product.
– Never remove or insert the plug connector while live.
– Operate the product only in an installed condition when all required protective
measures have been taken è EN 60204-1.
– Before working on the product, switch off the power supply and secure it
against being switched on again.
– Store the product in a cool, dry environment protected from UV and corrosion.
Keep storage times short.
2.2

Intended use

The intended use of the EMCS-ST integrated drive is to power the connected
actuator technology. The integrated electronics enable control of position, speed
or force/torque.
2.2.1

Application areas

The device is intended for use in an industrial environment. Outside industrial
environments, e.g. in commercial and residential/mixed-use areas, it may be
necessary to take measures to suppress radio interference.
2.3

Training of qualified personnel

Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers.
The qualified personnel have knowledge and experience in dealing with electric
drive systems.
2.4

Approvals and certifications

CE approval (conformity)
In conjunction with the CE mark on the product, the EC directives and standards
listed below in the Declaration of Conformity è www.festo.com/sp apply.
– in accordance with EU EMC Directive
– in accordance with EU RoHS Directive
KC certification
KC number: R-R-FTO-KC-2018-1082
RCM certification
The product fulfils the EMC requirements for Australia and New Zealand with the
RCM certification mark on the product.
3

Additional information

– Contact the regional Festo contact if you have technical problems
è www.festo.com.
– Accessories and spare parts è www.festo.com/catalogue.
4
4.1

Scope of delivery

The following components are included in the scope of delivery:
– Integrated drive EMCS-YY-ST-... (Spare part)
– Instruction manual for the integrated drive EMCS-YY-ST
EN 61800-5-1:2016-08
EN 60034-1:2011-02
EN 60204-1:2006+A1:2009+AC:2010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EMCS ST Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Festo EMCS ST Series

  • Page 1 – Do not carry out repairs on the product. Replace defective product immediately. – Observe the identifications on the product. © 2022 all rights reserved to Festo SE & Co. KG – Never remove or insert the plug connector while live.
  • Page 2 Connecting IO-Link directly to the master 5. Commission the drive system è 10 Commissioning. 6. Update the parameter set è 10.2 Parameter set. 7. Update the firmware (optional) è "Integrated drive EMCS" instruction manual è www.festo.com/sp. Demounting WARNING Unexpected movement of components.
  • Page 3 Requirement for the IO-Link master/application software – The IO-Link master must support the IO-Link standard "IO-Link BLOB Transfer & Firmware Update V1.1", e.g. the Festo USB IO-Link Master CDSU-1 with firmware version V2.1.0.11 or higher. – An IODD device description file with version V1.2.6 or higher is used in the application software.
  • Page 4 The table shows all steps for updating the parameter set using the application software of the Festo USB IO-Link Master CDSU-1 as an example. Steps for updating the parameter set 1. Start the application software –...
  • Page 5 7. Open the IODD file of the drive unit (device description file) – The connection is established 2 4. Open the parameter set file (e.g. Festo-EGSS_...-20210209-IOLFW1.0.iolfw) Variants for opening the file: – Open the "File" tab and execute the "Open IODDs" submenu 1 –...
  • Page 6 Steps for updating the parameter set Steps for updating the parameter set 8. Eliminate incompatibility errors. Only if the error in question is displayed. 11. Initialise end positions "Lim / Lim " and reference end position "Ref" With error message "Parameter package download error - parameter set incompatible". –...

Table of Contents