Zoom G1X Service Manual page 14

Hide thumbs Also See for G1X:
Table of Contents

Advertisement

Initialization
ALL
This startup recovers the factory default condition.
Refer to page 10.
Pedal calibration
Used to readjust the expression pedal operation.
Refer to page 26 of the G1/G1X operation manual.
● Pre-select
See the Operation Manual.
● Back up user's data
This startup is used for back up user's data.
Refer to page 8.
● Version
The 7 segment LED is displayed system version of the G1.
* It is displayed in four digits.
1) Start up holding the [BANK UP・TAP] key (SW1) and
the FOOT SWITCH [^] (SW5).
Make sure "00" appears on the 7 segment LED.
2) Press the FOOT SWITCH [^](SW5) or [v] (SW4).
i) Serial No. 000001 - 022150
Make sure "10" appears on the 7 segment LED.
ii) Serial No. 022151 –
Make sure "12" appears on the 7 segment LED.
3) Restart the G1X by press the FOOT SWITCH [^] (SW5) or [v] (SW4) again.
● Revision
The 7 segment LED is displayed system revision of the G1.
* It is displayed in four digits.
1) Start up holding the [RHYTHM] key (SW2) and
the FOOT SWITCH [v] (SW4).
Make sure "00" appears on the 7 segment LED.
2) Press the FOOT SWITCH [^] (SW5) or [v] (SW4).
i) Serial No. 000001 - 022150
Make sure "46" appears on the 7 segment LED.
ii) Serial No. 022151 –
Make sure "48" appears on the 7 segment LED.
3) Restart the G1X by press the FOOT SWITCH [^] (SW5) or [v] (SW4) again.
- 14 -