Connecting Low DC Power

To connect a low DC power supply to the device, do the following:
Electrical hazard – risk of damage to equipment
Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block.
Damage to the power supply may occur.
Note
The RUGGEDCOM RX1501 works with both positive VDC power supplies and negative
VDC power supplies.
RUGGEDCOM RX1501
Installation Manual, 04/2022, C79000-G8976-1054-22
Using a #10 ring lug and #10-32 screw, secure the ground terminal on the
power source to the ground connection on the device. Make sure the lug is
tightened to 1.1 N·m (9.5 lbf·in).
#10 Ring Lug
1
#10-32 Screw
2
Connection from External Power Source
3
Ground Connection
4
Figure 2.8
Ground Connection
Install the safety cover over the terminal block.