Multi-Zone Operations; Emergency Operation - Sea Breeze SHE9H4ZIGB Installation And User Manual

Hide thumbs Also See for SHE9H4ZIGB:
Table of Contents

Advertisement

42K BTU - Quad Zone Configurations
Note: 1. Do not mismatch or connect to an outdoor unit other than the designed matched system.
2. This system must be used with a minimum of two indoor units (evaporators).
2 INDOOR UNITS
9K + 9K
9K + 12K
9K + 18K
12K + 12K
12K + 18K
18K + 18K
12K + 21K
12K + 24K
18K + 21K
18K + 24K
21K + 21K
21K + 24K
The system matches below are not recommended if all indoor units may require simultaneous continuous duty at full efficiency.
24K + 24K
The Multi-Zone mini-split will operate each zone in either cooling or heating mode but not both. The unit will not
operate as one zone cool and another heat. If this occurs, an E7 error will be displayed. To clear this error, make
sure all indoor units are in the same mode either heat or cool. Each zone will control the room temperature at
set-point and allow all normal fan, swing, turbo, timer, and sleep functions
Emergency Operation (Aux. Switch)
In the event that the remote controls are misplaced, you can operate your
inside unit by carefully raising the cover and pressing the emergency
operation switch located under the lower right hand corner of the cover.
To open the front cover, place fingers in the bottom of the slots on the side
of the indoor unit and gently pull outward. To close the cover, press down on each end and center of
the cover to latch.
DO NOT OVER EXTEND THE FRONT COVER.
If the unit is off, pressing the Aux. button will start the unit
in the default AUTO mode. Press the button again and it
will stop the unit.
Temperature is automatically set to 68 ° F to 77° F and will
switch between COOL, HEAT or FAN mode to maintain
the temperature. If the temperature goes below 68 ° F the
unit switches to HEAT mode. If the temperature goes above 77 ° F unit switches to COOL mode. If
temperature is in between 68 ° F to 77° F the unit runs in the FAN mode.
950-0234revC
3 INDOOR UNITS
9K + 9K + 9K
9K + 9K + 12K
9K + 9K + 18K
9K + 12K + 12K
9K + 12K + 18K
9K + 18K + 18K
12K + 12K + 12K
12K + 12K + 18K
12K + 18K + 18K
9K + 9K + 21K
9K + 12K + 12K + 12K
9K + 9K + 24K
9K + 18K + 21K
9K + 12K + 21K
9K + 12K + 24K
12K + 12K + 21K
18K + 18K + 18K
9K + 12K + 12K + 18K
9K + 18K + 24K
9K + 12K + 12K + 21K
9K + 21K + 21K
12K + 12K + 12K + 18K
9K + 21K + 24K
12K + 18K + 21K
12K + 18K + 24K
12K + 21K + 21K
12K + 12K + 12K + 12K
12K + 12K + 24K
MULTI-ZONE OPERATION
- 6 -
4 INDOOR UNITS
9K + 9K + 9K + 9K
9K + 9K + 9K + 12K
9K + 9K + 9K + 18K
9K + 9K + 12K + 12K
9K + 9K + 12K + 18K
9K + 9K + 18K + 18K
9K + 9K + 9K + 24K
9K + 9K + 12K + 21K
9K + 9K + 12K + 24K
9K + 9K + 9K + 21K
.
5 INDOOR UNITS
9K + 9K + 9K + 9K +9K
9K + 9K + 9K + 9K + 18K
9K + 9K + 9K + 12K + 12K
9K+ 9K + 12K + 12K + 12K
9K + 9K + 9K + 9K + 12K
Aux. Button