symbol
, or coloured green and
yellow.
2. Connect the blue (neutral) wire to the
terminal in the plug which is marked
with the letter 'N' or coloured black.
3. Connect the brown (live) wire to the
terminal in the plug which is marked
with the letter 'L' or coloured red.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly
attached on the outer sheath.
Warning! Be careful when you
dispose of the cut off plug. It is
dangerous to put a cut off plug
into a 13 amp socket. There is a
risk of electrical shock.
Only a qualified electrician can
replace the electrical cable,
according to the current
regulations.
Replacement of the connection cable
Warning! To replace the
connection cable, the technician
must have a specific equipment.

Gas connection

Warning! Refer to Safety
chapters.
Caution! Information for
authorised installer only.
Connection to main pipe
Warning! This appliance is not
connected to a combustion
products evacuation device.
Before you proceed with the
installation, make sure that the
local distribution conditions,
nature of the gas and gas
pressure, and the adjustment of
the appliance are compatible.
In this case, only cable type H03V2V2-F T90
must be used. The cable section must be
suitable to the voltage and the working
temperature. The yellow and green earth
2
wire
must be approximately 2 cm longer
than the brown or black phase wire
The installation must be compliant with the
current local regulations. Complying with the
local regulations, the connection of the
cooktop to the gas pipe network or gas
cylinder must be made by means of a rigid
copper or steel pipe with fittings, or by
means of a continuous surface stainless
steel hose.
If there is a problem with the
pipe, do not repair it yourself.
Contact the local After Sales
Service Provider. Refer to the
Service chapter.
The connection must be installed correctly
and fixed into the hob connection pipe.
Otherwise, gas may leak from the
connection pipe.