Download Print this page

Lytham Lift 2; Technical Characteristics - Supra LYTHAM LIFT 2 Instructions For Installation And Use Manual

Advertisement

1.
TECHNICAL
1.
TECHNICAL
STOVE
Category of stove
(1)
Rated heating output
Operation with door closed only
Type of connection
Efficiency
Average temperature of smoke with the door closed
CO rate (13% O 2 )
CO2 rate (13% O 2 )
Dust level (13% O 2 )
FUEL
Log size
Nominal hourly load
Reloading interval
Alternative fuel
Prohibited fuels
Mass flow of smoke
Nominal diameter of smoke outlet
CHARACTERISTICS OF THE SMOKE FLUE
Minimum dimensions of chimney block
MIN Ø tubing or insulated metal flue
Min. height of flue above appliance
Ventilation of the room
DRAUGHT (10 PA = 1 MM CE)
Nominal speed
reduced speed (min. admissible)
Max. admissible
Approx. basic net/gross weight
Manufacturer's plate
ACCESSORIES PROVIDED
Insulated glove
1 LYTHAM LIFT 2 DIMENSIONS
CHARACTERISTICS
CHARACTERISTICS
all others, including coal and derivatives
on the back of the appliance

LYTHAM LIFT 2

Intermittent
5.5 kW
vertical
80 %
270°C
0.14 %
10.3 %
31 mg/Nm
3
firewood
25 cm / 33 cm
1.6 kg/hr
45 min
lignite
4.6 g/s
125 mm
20 x 20 cm
125 mm
4 m
1.2 dm²
12 Pa ± 2 Pa
6 Pa ± 1 Pa
20 Pa
86/106 kg
GB-3/8
38884-08-16

Advertisement

loading