Trane 2/4TGB3F42A Installer's Manual

3-1/2 – 4 ton air handlers upflow / horizontal left

Advertisement

Installer's Guide
3-1/2 - 4 Ton Air Handlers
Upflow / Horizontal Left
2/4TGB3F42A 2/4TGB3F48A
WARNING:
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT - This Document is customer property and is to remain with this unit. Please return to service informa-
tion pack upon completion of work.
A. GENERAL INFORMATION
WARNING
!
THIS INFORMATION IS FOR USE BY INDIVIDUALS
HAVING ADEQUATE BACKGROUNDS OF ELECTRICAL
AND MECHANI CAL EXPERIENCE. ANY ATTEMPT TO
REPAIR A CENTRAL AIR CONDITIONING PROD-
UCT MAY RESULT IN PERSONAL INJURY AND/OR
PROPERTY DAMAGE. THE MANUFACTURER OR
SELLER CANNOT BE RESPONSIBLE FOR THE IN-
TERPRETATION OF THIS INFORMATION, NOR CAN
IT ASSUME ANY LIABILITY IN CONNECTION WITH
ITS USE.
CAUTION
!
To prevent shortening its service life, the air
handler should not be used during the finishing
phases of construction. The low return air tem-
peratures can lead to the formation of conden-
sate. Condensate in the presence of chlorides and
fluorides from paint, varnish, stains, adhesives,
cleaning compounds, and cement creates a corro-
sive condition which may cause rapid deteriora-
tion of the cabinet and internal components.
These instructions do not cover all variations in sys-
tems or provide for every possible contingency. Should
further information be desired or particular problems
arise which are not covered sufficiently by this manu-
al, contact your local distributor or the manufacturer
as listed on the air handler nameplate.
These Air Handlers are vertical upflow and horizontal
left configuration only. Refer to Section B beginning on
page 2 for additional information.
INSPECTION
Check carefully for any shipping damage. This must be
reported to and claims made against the transporta-
tion company immediately. Check to be sure all major
components are in the unit. Any missing parts should
be reported to your supplier at once, and replaced with
authorized parts only.
© 2008 Trane
HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
CONTENTS
General Information ............................................... 1
Installation Limitations & Recommendations ............................. 1
Unit Installation ...................................................... 2
Vertical Upflow .......................................................................... 2
Horizontal Left ........................................................................... 3
Refrigerant Piping .................................................. 3
Condensate Drain Piping ...................................... 4
Electrical - Wiring ................................................... 5
Hook Up Diagrams .................................................. 5
Outline Drawings .................................................... 7
Checkout Procedures ............................................. 8
INSTALLATION LIMITATIONS & RECOMMENDATIONS
The general location of the air handler is normally se-
lected by the architect, contractor and/or home owner
for the most effective application and satisfaction.
These air handlers are suitable for installation in a
closet, alcove or utility room with free, non-ducted, air
return, using the area space as a return air plenum.
With ducted supply air, if the minimum clearances to
combustible materials and service access are observed,
the above installations are suitable.
NOTE:
Condensation may occur on the
surface of the air handler when installed in
an unconditioned location. When units are
installed in unconditioned spaces, verify
that all electrical and refrigerant line pen-
etrations on the air handler are sealed com-
pletely.
This area may also be used for other purposes, includ-
ing an electric hot water heater - but in no case shall
a fossil fuel device be installed and/or operated
in the same closet, alcove or utility room.
18-GD07D1-5

Advertisement

Table of Contents
loading

Summary of Contents for Trane 2/4TGB3F42A

  • Page 1: Table Of Contents

    Installer’s Guide 18-GD07D1-5 3-1/2 – 4 Ton Air Handlers Upflow / Horizontal Left 2/4TGB3F42A 2/4TGB3F48A WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service informa- tion pack upon completion of work.
  • Page 2: Unit Installation

    Installer’s Guide In addition, these air handlers are suitable for instal- applicable local codes may limit this air handler to lation in an attic, garage or crawl space with ducted installation only in a single story residence & with- supply and return air. in conditioned space.
  • Page 3: Horizontal Left

    Installer’s Guide d. Position unit on Pedestal or other suitable foun- located in the accessory kit shipped with the unit and dation. If Pedestal is not used, a frame strong one is installed on the discharge opening. If the duct enough to support the total weight must be pro- flanges are not needed, the installed flange must be vided.
  • Page 4: Condensate Drain Piping

    Installer’s Guide F. CONDENSATE DRAIN PIPING Manufactured traps OTE: Make certain that the unit has been installed in a level position to ensure proper draining. The indoor blower is downstream of the evaporator coil which creates a negative pressure at the condensate 2"...
  • Page 5: Electrical - Wiring

    Installer’s Guide G. ELECTRICAL — POWER WIRING NOTE: If air handler is used with or without a heater, the 1. These Air Handlers are shipped from the factory 7/8" electrical entry hole as well as any other cabi- wired for 230 volts. The units may be wired for 208 net penetrations must be sealed air tight.
  • Page 6 Installer’s Guide 2/4TGB AIR HANDLERS WITH SINGLE SPEED HEAT PUMP 2/4TGB AIR HANDLERS WITH SINGLE STAGE COOLING AND TWO STAGE HEATING From Dwg. B801081 Rev. 2 18-GD07D1-5...
  • Page 7: Outline Drawings

    Installer’s Guide 18-GD07D1-5...
  • Page 8: Checkout Procedures

    I. CHECKOUT PROCEDURE 1. Check the Air Handler installation in accordance with this instruction. 2. “Operational Procedure” for the system installation can be found in the outdoor unit installer guide and will be compatible with this Air Handler. CHECKOUT PROCEDURES After installation has been completed, it is recommended that the Air Handler be checked against the following checklist.

This manual is also suitable for:

2/4tgb3f48a

Table of Contents