Replacing the Presser Foot Return Spring and Washer (1)
Setscrew A
Hexagonal socket
screw
Setscrew B
Presser foot
Cushion
Setscrew A
Needle clamp screw
22
Step 1: Open the Needle Change Adjusting
Window of the Factory Adjusting Mode.
Turn the power switch on while pressing the Start/ Stop
button and Thread cutter button at the same time to open
the Factory Adjusting window.
Select needle bar No. 1.
Step 2: Removing the Needle Bar
1. Remove the thread tension panel, lower thread guide
plate and thread catcher panel (see page 8).
2. Remove the 2 setscrews A and the tension control unit.
3. Loosen the needle clamp screw and remove the needle.
4. Lower the needle bar. Loosen the hexagonal socket
screw and remove the needle clamp.
5. Remove the setscrew B, presser foot and cushion.