Download Print this page

Elitech V700 User Manual page 12

Intelligent vacuum pump

Advertisement

How to replace the vacuum pump oil
1. Run the pump for about 3-5minutes until it is warmed up to runs out the pump oil.
2. When the pump is running, open the air inlet port at the same time to let the oil flow
back to the oil tank. The pump must stop when replacing the oil.
Stop the pump and open the oil drain plug. Then open the catcher to speed up the
process of oil exhausting.
3. Tilt the pump body to completely drain the residual oil, and tighten the drain plug.
4. Open the catch device and add the new pump oil.
5. Cover the air inlet cap and start the pump to run-check the oil level after one
minute.If the oil level is below the lower limit, slowly add the oil until it reaches the
normal oil level. Finally, screw on the catcher.
Troubleshooting Guide
Failure
Cause of Issue
Phenomenon
1. Insu cient Oil
2. Pump oil Emulsified, Polluted
3. The Oil Inlet Is Blocked or the Oil
Supply is Insu cient
4. Leakage of the Pump System and
Low Vacuum
Connection
5.
Improper Selection of Pump
6. Parts Wear and Tear due to Long
Time Used.
1.
The Oil Seal Is Damaged
Oil Leakage
2.
Loose or Damaged Tank
Connections
Troubleshooting Method
Add oil between the maximum and minimum
level
Replace with new oil
Clean the oil inlet and filter
Check the system and the connection to
prevent the leakage
Check the size of the pumped container,
recalculate and select the appropriate type of
pump
Repair or replace with a new pump
Replace oil seal
Tighten the screws and replace the O -ring