  • Page 1 3-Phase Wall-Box 11KW with 5m standard charger cable Quick Installation Guide DN-3P16-050 – Rev 1.0...
  • Page 2 Please read this manual carefully before installation and use, otherwise, it may interfere with the normal use of the equipment and even risk causing personal injury. Safety and Points for Attention 1.1. Installation Installation must be carried out by personnel with ...
  • Page 3 Electrician/Installers. Improper operation may cause damage to the equipment. Do not put inflammable, explosive or combustible  materials, chemicals, combustible steam and other dangerous goods near the charging station, otherwise there is a risk of fire. Please keep the charging adapter clean and dry and ...
  • Page 4 Flame Lightning-proof resistance Overvoltage Waterproof protection IP55 Overcurrent Leakage protection protection Overheat IEC 62196-2 protection (Type 2) connector...
  • Page 5: Package Content

    2. Feature Compact size design with charging power up-to 11kW. • Charging plug meet IEC 62196-2 (Type 2) standard. • • Charging adapter is with IP55 waterproof rating for outdoor usage. EV Charger meets IEC 61851 control principle • Long durability: Charging adapter at no-load plug in/ •...
  • Page 6: Technical Specification

    4. Technical Specification Charging mode Mode 3 Input Voltage 3-phase AC, 400V±15% Rated frequency 50/60Hz Branch breaker Electric parameters Input circuit L1/ L2/ L3/ N/ PE conductor Copper cable is recommended with appropriate conductor size. Charging control Direct “Plug-and- charge” Display screen Indicator lights LED light indicator...
  • Page 7 Mounting Wall-mounted Charging adapter IEC 62196-2, Type 2 Charging cable length Mechanical parameters Dimension 310mm × 161mm × (H×W×D) 79.8mm Weight ≤5kg IP rating IP55 Operational Indoor or outdoor, environment good ventilation, no flammable, explosive gases Vibration No violent vibration and impact Environmental conditions...
  • Page 8: Product Dimension

    5. Product Dimension 6. Internal Wiring on AC Terminal Block AC Input Cable Pin Definition L3 L2 L1 N PE...
  • Page 9: Installation Process

    7. Installation process Position the mounting bracket at the desired height or following the recommendation below. Install the bracket onto the wall with the screws packed inside the package...
  • Page 10 Open the back-cover of the Charger and pre-install the AC input cables following the pin definition on the Terminal Block. AC Input Cable Pin Definition L3 L2 L1 N PE...
  • Page 11 Mount the EV Charger onto the wall by hanging it on the installed bracket. Install another screw from the front to lock it.
  • Page 12 It is recommended to install the Charging adapter hook onto the wall at an installation height of 800mm from the ground...
  • Page 13 To complete the installation with an external circuit breaker at the input side.
  • Page 14: Power-On Inspection

    8. Power-on inspection 8.1. Check before operation Before operation, please check carefully and ensure the following: • The installation position of the EV Charger is convenient for operation and maintenance • The EV Charger and its accessories are correctly connected and installed firmly Reasonable selection of leakage protection switch for AC •...
  • Page 15 If your EV Charger is showing RED color, please check below LED status for error code or contact the manufacturer 8.3. Start charging Park the electric car into place, turn off the engine, and put the car under braking. Pick up the charging adapter from the Charger after Charger is showing Green light constant ON after power- on self-test.
  • Page 16 8.5. Abnormally stop charging Forced fault stop: A fault stop initiated by the onboard charger of vehicle. Automatic fault stop: A fault stop initiated by the charging station due to internal protection mechanisms 9. LED indicator for Status and Error codes LED Color Indicator Index Description Definition...
  • Page 17 During charging, Charging the Blue light Flashes starts flashes as charging in progress When charging Charging finishes, the Blue light will be finishes constant ON When Control Pilot pin detects Control Fault error during Pilot (0.5s) handshaking Pin Error 1 time with Electric vehicle Fault...
  • Page 18 When RCD detects leakage, the relay automatically disconnected the system. It needs to Fault be re-powered Leakage (0.5s) after the fault is Detected 4 time removed before the relay is allowed to close to function again When over current is detected, the relay is disconnected then Fault...
  • Page 19 When wall-box is powered-on each time, it will trigger RCD leakage Fault a self-check for detection (0.5s) RCD leakage self-check 7 time detection. If RCD is not working, it will flash red color LED 7x times. When the emergency stop button is pressed on the side of the wall-box, it will...
  • Page 20 Hereby Assmann Electronic GmbH, declares that the Declaration of Conformity is part of the shipping content. If the Declaration of Conformity is missing, you can request it by post under the below mentioned manufacturer address. www.assmann.com Assmann Electronic GmbH Auf dem Schüffel 3, 58513 Lüdenscheid Germany...