For Ethernet switch or router that supports QoS, packets higher CoS priority should be transmitted first if network traffic is congested. DApps-QoS can limit acceptable network traffic at receiving port, analyze the traffic distribution of packets with different priority received from router or switch, and test the performance of Layer 3 Router, Switch with QoS function.
With its unique Universal Stream Counter (USC), NuDOG-301C offers real-time statistics of network events during packet monitoring and capturing. With these advantageous features, NuDOG-301C is your best partner for LAB researching and in-field troubleshooting. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Both NuDOG-301C's Port A and Port B can generate and receive test streams. The test streams are sent and returned to the same NuDOG-301C for DUT (device under test) analysis. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ®...
Page 8
(port A and port B) and also provides abundant packet counters. In Loopback mode, NuDOG-301C resends the incoming streams back to the source. NIC Mode In this mode, NuDOG-301C simulates network interface card (NIC). E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
I Port A - RJ45 Port 10/100/1000 Mbps Half/Full RJ45 Port A *Please note that when connecting NuDOG-301C with PC via its USB port, DO NOT use a USB hub E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ®...
The RJ45 Port is connected to DUT/Network Link/ACT Green Blinking NuDOG-301C is transmitting or receiving data Green ON 1000Mbps connection Speed Green Blinking 100Mbps connection 10Mbps connection if Link/ACT is ON or blinking E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
RFC 2889, RFC 2544, and QoS. With these utilities, NuDOG-801 is able to conduct throughput test, latency test, error filtering test, forwarding test, and so on. Xtramus’ utility softwares provide a user-friendly interface for different test configurations when setting test parameters and criteria.
Both NuDOG-801’s Port A and Port B can generate and receive test streams. The test streams are sent and returned to the same NuDOG-801 for DUT (device under test) analysis. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Page 13
(port A and port B) and also provides abundant packet counters. In Loopback mode, NuDOG-801 resends the incoming streams back to the source. NIC Mode In this mode, NuDOG-801 simulates network interface card (NIC). E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
8-Pin Mini-DIN Receptacle Diagnostic Port 10 Gigabit Wirespeed 10 Gigabit Wirespeed SFP+ Port SFP + Port *Please note that when connecting NuDOG-801C with PC via its USB port, DO NOT use a USB hub E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Yellow Blinking CRC error or packet loss is occurring Error/Loss No CRC error or packet loss is occurring Green ON The RJ45 Port is connected to DUT/Network Link/ACT Green Blinking NuDOG-801 is transmitting or receiving data E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
With its unique Universal Stream Counter (USC), NuDOG-101T offers real-time statistics of network events during packet monitoring and capturing. With these advantageous features, NuDOG-101T is your best partner for LAB researching and in-field troubleshooting. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Both NuDOG-101T’s Port A and Port B can generate and receive test streams. The test streams are sent and returned to the same NuDOG-101T for DUT (device under test) analysis. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ®...
Page 18
(port A and port B) and also provides abundant packet counters. In Loopback mode, NuDOG-101T resends the incoming streams back to the source. NIC Mode In this mode, NuDOG-101T simulates network interface card (NIC). E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
NuDOG-101T Hardware Overview A Mini-USB Port for connecting NuDOG-101T to PC or for power supply. B LEDs that display NuDOG-101T’s system status. C Interface Port A/B for connecting NuDOG-101T to DUT or network. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Port A/B is under Capturing Mode Green ON The RJ45 Port is connected to DUT/Network Link/ACT Green Blinking NuDOG-101T is transmitting or receiving data Green ON 100Mbps connection Speed 10Mbps connection if Link/ACT is ON or blinking E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
5. Installing/Uninstalling DApps-QoS Please follow the steps down below to install DApps-QoS. Also, please note that DO NOT connect your NuDOG-301C to your PC before DApps-QoS is properly installed on your PC. Installing DApps-QoS Double-click DApps-QoS installation program and start the installation process*.
Page 22
Click “I accept the terms in the license agreement”, and click “Next” to continue. You can input User Name and Organization in the related fields. Click “Next” to continue. DApps-QoS InstallShield Wizard will start installing momentarily. Click “Install” button to continue. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ®...
Page 24
You can uninstall DApps-QoS by: Uninstalling DApps-QoS Click Start All Programs Xtramus DApps-QoS Uninstall DApps-QoS. Go to the Control Panel, choose DApps-QoS, and uninstall the program. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
6. DApps-QoS Functions Overview 6.1. Starting DApps-QoS Before starting DApps-QoS, your PC and NuDOG-301C/NuDOG-801/NuDOG-101T shall be connected properly. The figure down below illustrates connecting PC and NuDOG-301C. You can connect NuDOG-801/NuDOG-101T with PC in the same manner. There are two ways to start DApps-QoS: Starting DApps-QoS ...
Page 26
DApps-QoS Demo Mode If your PC is not connected with NuDOG-301C/NuDOG-101T, you can still run DApps-QoS under Demo Mode. Almost all DApps-QoS’s functions are available under Demo Mode. However, please note that Demo Mode is for system demo purposes only, and does not serve any testing purposes at all.
The Elapsed Time field displays the elapsed time during test. Description The Description field display brief descriptions regarding to tests. Status Bar The Status Bar shows the running status of DApps-QoS. Control Buttons/Test The Control Buttons allow you to start/stop tests, and the Test Running Running Status Icon Status Icon indicates if there’s a test running.
7. DApps-QoS Functions 7.1. Menu Bar DApps-QoS Menu Bar includes configuration options such as File, View, Language, Tool, and Help. Please refer to the sections down below for detail information regarding to each configuration option. 7.1.1. File File If you have a previously saved...
Module Info. This function is temporarily unavailable to use. 7.1.3. Language Language By default, the DApps-QoS’s UI illustration language is based on English. There English are no other language options for the users to choose by now. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ®...
You can name your Tester in this field. The default name is New Tester. Min. Waiting Time The minimum waiting time (in seconds) for auto-negotiation. Auto If the time (in seconds) DApps-QoS spent for Media Type Negotiation auto-negotiation exceeds the time you set here, the test will Change Timeout stop.
PC and the FPGA/Firmware of the module. System Requirements OK: Click this button to exit the “System Requirements” pop-up window. Xtramus Web Open your default web browser and access Xtramus Website (www.xtramus.com). E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Save Config button on the Quick Launch Buttons. Configuration files are saved in the format of “*.xml”, and are named with Tester Name, DUT Name, and the date/time when files are created. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Page 33
By clicking the Port Config button, the Port Configuration screen will be shown on the Main Display Screen located on the right side of DApps-QoS’ main window, allowing you to make settings for the module ports. Settings such as port transmitting rate and auto-negotiation are available and can be set here.
Page 34
Report The Report button allows you to view test results, charts, and statistics on the Main Display Screen located on the right side of DApps-QoS’ main window. For more detail description about Report, please refer to 6.10. Report. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ®...
By clicking the System Information on the System Info/Port Configuration List, the System Information screen will be shown on the Main Display Screen located on the right side of DApps-QoS’ main window. Port Configuration By clicking the Port Configuration on the System...
Info/Port Configuration List, the Test Configuration screen will be shown on the Main Display Screen located on the right side of DApps-QoS’ main window, allowing you to make test settings. You can set the Port Pair and 6 different test modes here, including Throughput, Packet Loss, Latency, Latency Overtime, Latency Snapshot and Jitter.
7.6. Status Bar The Status Bar shows the running status of DApps-QoS. 7.7. Control Buttons/Test Running Status Icon The Control Buttons allow you to start/stop tests, and the Test Running Status Icon indicates if there’s a test running. Control Buttons...
There are two ways to access Port Config: Accessing Port Config Click Port Config located on System Info/ Port Configuration List Click the Port Config button located on Quick Launch Buttons. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
SMAC&DMAC here by double clicking the column. Alias: You can input alias for identifying active ports here in these fields. Speed: The Speed scroll-down menu allows you to set each port’s transmitting/receiving rate. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Protocol: Select the protocols of layer2 or layer3. Type: service types. This function is only available when you select layer3 protocols. Choose Diff or ToS from the scroll down menu. Apply: Apply the settings you’ve made here. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Main Display Screen. There are two ways to access Test Config: Accessing Test Config Click Test Config located on System Info/ Configuration List Click the Test Config button located on Quick Launch Buttons. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Page 44
Latency, Latency Overtime, Latency Snapshot and Jitter, which can be accessed by clicking the test you would like to perform on System Info/Configuration List or the tab menu located on Test Configuration screen. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Page 45
Assigning Source Port and Destination Port for DApps-QoS Before making any test configurations on the Test Configuration screen, you have to assign the Source Port and Destination Port for DApps-QoS first. Please see the description down below for more details. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ®...
Page 46
Assigning Source Port and Destination Port for DApps-QoS Choose a port that will serve as the source port from the Source field and choose a port that will serve as the destination port from the Destination field. Note: For there are only two ports for the NuDOG...
Measures the Jitter periodic signal. To start performing tests with DApps-QoS, please check the check box in front of the test you would like to perform first. Unchecked tests will not be performed, and cannot access their reports as well during or after the tests.
Test method: DApps-QoS calculates frame loss as: Frame Loss = Number of Frames Transmitted - Number of Frames Received The general methodology of the Throughput test is: the test finds the maximum transmission rate at ...
Page 49
The test will stop when the difference between the current network traffic rate Resolution and the last network traffic rate is smaller than the value you set here. Acceptable Loss The acceptable rate of packet loss during the test. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
3. DApps-QoS calculates total frame loss and out of sequence frames for each group, and each flow in each group at that load percentage. 4. DApps-QoS then steps up the load and sends a frame burst for the specified period of time. It repeats Steps 2 and 3 until it reaches the maximum load specified.
Page 51
Number of Trials 1~100. The rate of packet transfer. You can also set the load unit in percentage or Tx Rate Mbps here. Maximum The maximum limit to receive packets in Mbps/sec. Receive E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Page 52
64 and 1518 bytes. This scroll-down menu allows you to set packet contents to Random, Increase, Packet Payload 0x55AA, 0x00FF, All 1 or All 0. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Test method: This test tracks the latency of each test frame on a frame-by-frame basis. DApps-QoS reads the time the sending port sent the frame (Transmit Time) and the time the receiving port recognizes the trigger frame (Receive Timestamp).
Page 54
64 and 1518 bytes. This scroll-down menu allows you to set packet contents to Random, Increase, Packet Payload 0x55AA, 0x00FF, All 1 or All 0. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Latency Overtime test can provide a finer view of latency behavior of the DUT's load tolerance limits. Test method: The time period is based on the value specified in the Time interval field. DApps-QoS reads the time the sending port sent the frame (Transmit Time) and the time the receiving port recognizes the trigger frame (Receive Time).
Page 56
This scroll-down menu allows you to set packet contents to Random, Increase, Packet Payload 0x55AA, 0x00FF, All 1 or All 0. Latency Overtime Time Interval You can set the time interval in this field for measuring the Latency Overtime. (sec.) E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Page 57
Test method: DApps-QoS reads the time the sending port sent the frame (Transmit Time) and the time the receiving port recognizes the trigger frame (Receive Timestamp).
Page 58
Latency Snapshot Capture frames Set the quantity of frames you want to capture per stream. per streams Capture Start Set the time point you want to start to capture the frames per stream. (sec.) E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Page 59
The Jitter test checks packet tags to verify that packets transmitted by other ports are received correctly, whether they are received in the correct sequence, and whether there are missing packets. DApps-QoS inspects the sequence tracking number in each frame to determine if frames were received in sequence.
Page 60
64 and 1518 bytes. This scroll-down menu allows you to set packet contents to Random, Increase, Packet Payload 0x55AA, 0x00FF, All 1 or All 0. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Latency Overtime, Latency Snapshop, Jitter) will be displayed on the Main Display Screen. DApps-QoS will switch testing table of each test automatically when finishing the current test and starting the next test. Please note that you can only access the testing table for test you’ve performed.
Page 62
Display the detailed test data of each stream. E. Result Chart Display the test result in a chart format for a more intuitive perception. F. Port&Test Display the test ports and the name of the test. Info E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Page 63
This chart uses Rx packet quantity as Y-axis, and This chart uses Packet Loss Rate (%) as Y-axis, Frame Size as X-axis to show DUT’s throughput and Frame Count per Second as X-axis to show performance. DUT’s packet loss ratio. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
Page 64
Y-axis, and time in seconds as X-axis. Also, you can view test results counter by clicking the Report tab as shown on the figure down below. All statistics will be displayed in this table in detail for test result analysis. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ®...
Page 65
You can save the test results by: Saving Test Results Click FileSave Report Save Path to… on your Menu Bar. Click Save Report on your Quick Launch Buttons. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ® Website: www.Xtramus.com...
The utility of DApps-MPT can load testing models easily. All simple and visualized results and detailed testing logs are available to access upon demand. DApps-MPT is a powerful and convenient tool to apply on this device. E-mail: sales@xtramus.com XTRAMUS TECHNOLOGIES ®...